Siemens 3VA1112-6MH36-0AG0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-6MH36-0AG0 Circuit Breaker, 125A, 70kA @ 415

MPN3VA1112-6MH36-0AG0

Siemens 3VA1 IEC frame 160 circuit breaker, breaking capacity class H, 70 kA @ 415 V, 3-pole, 125 A, starter protection TM120M, AM, short-circuit protection Ii=5…15 x In, clamp connection, 1 auxiliary switch HP, 1 trip alarm switch HP.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1112-6MH36-0AG0 is a 3-pole IEC frame 160 molded case circuit breaker (MCCB) from the 3VA1 series, rated at 125 A with a breaking capacity of 70 kA at 415 V (class H). It is a starter-protection variant with a TM120M thermal-magnetic trip unit, set for motor starting duty without overload protection — meaning the thermal element is bypassed and only the magnetic short-circuit protection is active, adjustable between 5 and 15 times the rated current (Ii=5…15 x In). This makes it a magnetic-only breaker for motor short-circuit protection where overload protection is handled separately by a contactor/overload relay combination.

The magnetic-only trip (Ii=5…15 x In) means it will hold through motor inrush without nuisance tripping, but it will NOT provide overload protection; pair it with a properly sized overload relay on the contactor. The clamp connection accepts copper or aluminum conductors without lug kits, saving panel space and install time.

Where it lives in the panel

The 3-pole, 125 A frame fits in a standard MCCB footprint; plan for at least 75 mm of width per pole plus clearance for the auxiliary switch and trip alarm switch wiring.

Frequently asked questions

What is the breaking capacity of this breaker?

It has a breaking capacity of 70 kA at 415 V (IEC class H), suitable for high-fault-current applications.

Does this breaker provide overload protection?

No, this is a magnetic-only (starter protection) variant. It provides short-circuit protection only (Ii=5…15 x In). Overload protection must be provided by a separate overload relay in the motor starter.

Where can I buy the 3VA1112-6MH36-0AG0 and what is the price?

This part is available to order through independent distribution. Submit an RFQ for current pricing and availability confirmation.