Siemens 3VA1112-6MH36-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-6MH36-0CC0 Circuit Breaker, 70kA @ 415V, 125

MPN3VA1112-6MH36-0CC0

Siemens 3VA1 IEC frame 160 circuit breaker, breaking capacity class H, Icu=70kA @ 415V, 3-pole, starter protection TM120M, In=125A, Ii=5...15 x In, clamp connection, undervoltage release 120-127V AC, 2 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1112-6MH36-0CC0 is a 3-pole IEC frame 160 circuit breaker from the 3VA1 series, rated at 125 A with a breaking capacity class H — Icu=70kA @ 415V. This puts it squarely in the high-interrupting category for industrial panel feeders and motor branch circuits where fault currents can exceed 50 kA. The TM120M thermal-magnetic release provides starter protection (motor branch-circuit protection per IEC 60947-4-1), with an adjustable magnetic trip Ii=5...15 x In, meaning you can set instantaneous pickup between 625 A and 1875 A to coordinate with downstream contactors and overload relays.

For a 125 A feeder on a 415 V distribution board with transformer impedance giving a prospective fault current in that range, this breaker clears it without cascading upstream. The class H designation (70 kA) is the highest in the 3VA1 frame 160 lineup; standard class N (36 kA) and class S (50 kA) siblings exist if your SCCR study shows lower fault levels. Note the description states 'without overload protection short-circuit protection' — this variant ships with the TM release configured for magnetic (short-circuit) only; the thermal overload function is present but the breaker is ordered without the overload protection function enabled, intended for use with a separate overload relay downstream. The adjustable Ii=5...15 x In gives flexibility to coordinate with the motor locked-rotor current. When voltage drops below about 70% of rated, the UVR trips the breaker open — standard for applications where a motor must not auto-restart after a power dip. Two auxiliary switches (HQ — high-qualified, meaning high-reliability contacts) provide status feedback to the PLC or annunciator panel.

Deployment context

The 3VA1 frame 160 is a standard panel-building component — its footprint matches Siemens's SENTRON line, so it integrates into existing busbar systems and enclosure cutouts without modification. The UVR and aux switches are factory-installed, reducing field wiring time.

Frequently asked questions

What is the breaking capacity of this breaker?

The breaking capacity class H gives Icu=70kA @ 415V, suitable for high-fault industrial distribution.

What does the TM120M release mean?

TM120M is a thermal-magnetic release with starter protection characteristics, rated 125 A, with adjustable magnetic trip Ii=5...15 x In. This variant is configured for short-circuit protection only (no overload protection) and is intended for use with a separate overload relay.

Where can I buy 3VA1112-6MH36-0CC0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.