Skip to main content
Siemens 3VA1116-1AA32-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-1AA32-0AB0 SENTRON Switch Disconnector, 160

MPN3VA1116-1AA32-0AB0

Siemens SENTRON 3VA1116-1AA32-0AB0 switch disconnector, IEC frame 160, 3-pole, In=160 A, no overload or short-circuit protection, with 2 auxiliary switches HP, busbar connection, front terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1116-1AA32-0AB0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1116-1AA32-0AB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Power loss, max.38 W
3VA1116-1AA32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1116-1AA32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1116-1AA32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1116-1AA32-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

At 55 °C it holds 158 A, at 60 °C 155 A, at 65 °C 153 A, and at 70 °C 150 A. This is a pure disconnector — no overload or short-circuit protection inside. It isolates the load for safe maintenance or switching. It carries two auxiliary switches HP (high-performance) with 2 CO contacts. The main current circuit connects via busbar connection with front terminals. That's a panel-builder detail: you land busbars on the front face, not the back or sides, which simplifies busbar routing in a distribution board.

Mechanical service life is 15 000 operating cycles typical. That's adequate for a disconnector used for infrequent isolation; not for daily switching duty. Maximum power loss is 38 W at full load — factor that into panel thermal calculations if the cabinet is tightly packed. That covers cold storage and freezer environments — runs cold and stays cold down to -25 °C operating.

Frequently asked questions

Where can I buy 3VA1116-1AA32-0AB0 and get a price?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

What is the depth of 3VA1116-1AA32-0AB0?

The depth is 70 mm. Combined with a width of 76.2 mm and height of 130 mm, it fits the standard 3-pole MCCB footprint.

Will 3VA1116-1AA32-0AB0 drop into a panel specified around 3VA1110-5ED36-0AC0?

The 3VA1116-1AA32-0AB0 shares the same 76.2 mm width, 130 mm height, and 70 mm depth as the 3VA1110-5ED36-0AC0 (;). Both are 3-pole SENTRON 3VA1 frame 160 units with front terminals. The physical footprint is identical, so it drops into the same panel slot without rewiring. The functional difference is that the 3VA1116-1AA32-0AB0 is a switch disconnector with no overcurrent protection, while the peer is a molded-case circuit breaker with a TM210 release.

MPN
3VA1116-1AA32-0AB0