Skip to main content
Siemens 3VA1116-1AA32-0CH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-1AA32-0CH0 SENTRON Switch Disconnector, 160

MPN3VA1116-1AA32-0CH0

Siemens SENTRON 3VA1 IEC frame 160, switch disconnector SD100, 3-pole, In=160 A, busbar connection, front terminals, IP40 front, undervoltage release 120-127V AC, 2 aux switches HQ + 1 trip alarm switch HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1116-1AA32-0CH0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1116-1AA32-0CH0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W
3VA1116-1AA32-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1116-1AA32-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1116-1AA32-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1116-1AA32-0CH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Switch disconnector, not a breaker — what that means for your BOM line

The Siemens 3VA1116-1AA32-0CH0 is a SENTRON 3VA1 IEC frame 160 switch disconnector rated 160 A continuous (Iu) on a 3-pole body. The distinction matters for a BOM: this part opens and closes a circuit under load but does not trip on overcurrent. It sits in the same 70 mm deep × 76.2 mm wide × 130 mm high footprint as the 3VA1 MCCB siblings, using busbar connection on front terminals for the main circuit.

Undervoltage release and aux contact complement

The UVR has no leading contact, so the main contacts open directly on undervoltage without a time delay.

Ratings and environmental limits

Rated insulation voltage Ui is 800 V; maximum operational voltage is 690 V AC 50/60 Hz and 500 V DC. Short-time withstand is 2 kA at both 1 s and 0.5 s — this is the disconnector's fault-closing and short-time rating, not a breaking capacity. Mechanical endurance is 15 000 cycles. Maximum power loss is 38 W. Front protection is IP40; operating temperature range is -25 °C to +70 °C, storage -40 °C to +80 °C. The unit accepts busbar connection on front terminals, typical for panel-mount distribution.

Lifecycle status is listed as current production. This is an active catalog line within the Siemens SENTRON 3VA family.

Frequently asked questions

Will 3VA1116-1AA32-0CH0 drop into a panel specified around 3VA1110-5EE32-0DC0 without rewiring?

The 3VA1116-1AA32-0CH0 shares the same 70 mm depth, 76.2 mm width, and 130 mm height as the 3VA1110-5EE32-0DC0, and both use front-terminal busbar connection. However, the 3VA1110-5EE32-0DC0 is a molded case circuit breaker with lug terminals and overcurrent protection; the 3VA1116-1AA32-0CH0 is a switch disconnector with no overcurrent trip function. The physical footprint matches, but the functional difference — protection vs. isolation — means a direct swap changes the circuit's protection scheme.

MPN
3VA1116-1AA32-0CH0