Skip to main content
Siemens 3VA1116-1AA32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-1AA32-0HC0 SENTRON Switch Disconnector, 160

MPN3VA1116-1AA32-0HC0

Siemens SENTRON 3VA1116-1AA32-0HC0, IEC frame 160 switch disconnector, 3-pole, In=160 A, with shunt trip (STL) 12-30V DC / 24 V AC, 2 HQ auxiliary switches, busbar connection, front terminals, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1116-1AA32-0HC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1116-1AA32-0HC0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W
3VA1116-1AA32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1116-1AA32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1116-1AA32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1116-1AA32-0HC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Switch disconnector for 160 A isolation duty

Rated insulation voltage is 800 V, with maximum operational voltage 690 V AC 50/60 Hz or 500 V DC. Power dissipation maxes at 38 W, which should be factored into enclosure thermal calculations for a multi-breaker lineup.

What this part is for — and what it isn't

This is a switch disconnector, not a molded case circuit breaker. It provides visible isolation and load-break capability at 160 A but has no overcurrent or short-circuit protection — no trip curve, no overload adjustment. The shunt trip (STL) is the only integrated release; there is no undervoltage release or communication module. The closest functional peer, the 3VA1110-5EE32-0JA0, is a full MCCB with a TM220 thermal-magnetic release and 100 A frame rating. That part offers LI protection (long-time and instantaneous) and a much higher interrupting capacity — 187 kA at 240 V — but lacks the switch-disconnector's pure isolation role. The 3VA1116-1AA32-0HC0 is the right choice when the upstream breaker handles fault clearing and you need a local disconnect with remote trip capability.

Dimensions: 76.2 mm wide (3-inch footprint), 130 mm tall, 70 mm deep. Front terminals accept busbar connection for the main circuit — common in panelboard and switchboard builds where a common bus feeds multiple disconnects. The shunt trip coil draws from a separate 12–30 V DC or 24 V AC supply — not from the main bus. Wire the control voltage through a remote E-stop or PLC output for load shedding. The two HQ auxiliary contacts (CO form) provide independent NO/NC feedback for status indication or interlocking. Suitable for indoor panel environments within those limits.

Frequently asked questions

Where can I buy 3VA1116-1AA32-0HC0 and get a price?

This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is the difference between this switch disconnector and the 3VA1110-5EE32-0JA0 MCCB?

The 3VA1116-1AA32-0HC0 is a pure switch disconnector with no overcurrent protection, rated 160 A with a shunt trip. The 3VA1110-5EE32-0JA0 is a full MCCB with a TM220 thermal-magnetic release, 100 A rating, and LI protection — it interrupts faults up to 187 kA at 240 V. Use the switch disconnector when upstream protection already exists and you need a local disconnect with remote trip.

Will 3VA1116-1AA32-0HC0 fit in a panel designed for 3VA1110-5EE32-0JA0?

Both parts share the same 76.2 mm width, 130 mm height, and 70 mm depth, so the physical footprint is identical. However, the 3VA1116-1AA32-0HC0 uses busbar connection on the main circuit, while the 3VA1110-5EE32-0JA0 uses lug terminals — verify busbar interface compatibility before swapping.

What are the key specs of 3VA1116-1AA32-0HC0?

Rated continuous current 160 A, 3-pole, rated insulation voltage 800 V, max operational voltage 690 V AC / 500 V DC, shunt trip STL 12-30V DC / 24 V AC, 2 HQ auxiliary contacts, IP40 front, 15 000 mechanical cycles, 38 W max power loss.

MPN
3VA1116-1AA32-0HC0