Skip to main content
Siemens 3VA1116-1AA32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-1AA32-0KA0 SENTRON Switch Disconnector, 160

MPN3VA1116-1AA32-0KA0

Siemens SENTRON 3VA1 switch disconnector, IEC frame 160, 3-pole, 160 A, without overload or short-circuit protection, shunt trip (STL) 220-250 V DC / 208-277 V AC, busbar connection, front terminal.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1116-1AA32-0KA0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON

Ratings

3VA1116-1AA32-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Power loss, max.38 W

Construction & Connection

3VA1116-1AA32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1116-1AA32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1116-1AA32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1116-1AA32-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

What it is and what it does

The Siemens 3VA1116-1AA32-0KA0 is a SENTRON 3VA1 switch disconnector in an MCCB-style housing, rated for 160 A continuous at 40 °C through 50 °C, derating to 150 A at 70 °C. It is a 3-pole, non-fused disconnect — no overload or short-circuit protection built in, so it serves as a manual load-break switch or isolator in a distribution panel. The shunt trip release (STL) operates on 220-250 V DC or 208-277 V AC, letting you remotely trip the disconnect via a control signal — useful for emergency-stop chains or remote load shedding. No undervoltage release or auxiliary contacts are fitted on this variant.

Panel fit and wiring

Dimensions are 70 mm deep, 76.2 mm wide, 130 mm tall — a standard 3-pole MCCB footprint that drops into SENTRON 3VA1 panelboards and distribution blocks. Main circuit connection is via busbar on front terminals; the supplied nut keeper kit simplifies torqueing on the busbar stack. Front-face protection is IP40 — fine for enclosed panel mounting; keep it behind a door or cover in washdown areas. Rated insulation voltage is 800 V, operating voltage up to 690 V AC or 500 V DC.

Frequently asked questions

What is the closest functional alternative to 3VA1116-1AA32-0KA0?

The 3VA1112-5EE32-0AA0 is a molded case circuit breaker in the same 3VA1 frame (125 A, TM220 release) rather than a plain switch disconnector. It shares the same 70 mm × 76.2 mm × 130 mm footprint and busbar connection, so it will drop into the same panel cutout, but it includes overload and short-circuit protection — a different function. If you need a pure disconnect without protection, stick with the 3VA1116-1AA32-0KA0.

MPN