Skip to main content
Siemens 3VA1116-1AA32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-1AA32-0KA0 SENTRON Switch Disconnector, 160

MPN3VA1116-1AA32-0KA0

Siemens SENTRON 3VA1 switch disconnector, IEC frame 160, 3-pole, 160 A, without overload or short-circuit protection, shunt trip (STL) 220-250 V DC / 208-277 V AC, busbar connection, front terminal.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1116-1AA32-0KA0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1116-1AA32-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Power loss, max.38 W
3VA1116-1AA32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1116-1AA32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1116-1AA32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1116-1AA32-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1116-1AA32-0KA0 is a SENTRON 3VA1 switch disconnector in an MCCB-style housing, rated for 160 A continuous at 40 °C through 50 °C, derating to 150 A at 70 °C. It is a 3-pole, non-fused disconnect — no overload or short-circuit protection built in, so it serves as a manual load-break switch or isolator in a distribution panel. The shunt trip release (STL) operates on 220-250 V DC or 208-277 V AC, letting you remotely trip the disconnect via a control signal — useful for emergency-stop chains or remote load shedding. No undervoltage release or auxiliary contacts are fitted on this variant.

Dimensions are 70 mm deep, 76.2 mm wide, 130 mm tall — a standard 3-pole MCCB footprint that drops into SENTRON 3VA1 panelboards and distribution blocks. Main circuit connection is via busbar on front terminals; the supplied nut keeper kit simplifies torqueing on the busbar stack. Front-face protection is IP40 — fine for enclosed panel mounting; keep it behind a door or cover in washdown areas.

Frequently asked questions

What is the closest functional alternative to 3VA1116-1AA32-0KA0?

The 3VA1112-5EE32-0AA0 is a molded case circuit breaker in the same 3VA1 frame (125 A, TM220 release) rather than a plain switch disconnector. It shares the same 70 mm × 76.2 mm × 130 mm footprint and busbar connection, so it will drop into the same panel cutout, but it includes overload and short-circuit protection — a different function. If you need a pure disconnect without protection, stick with the 3VA1116-1AA32-0KA0.

MPN
3VA1116-1AA32-0KA0