3VA1116-1AA36-0AB0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1116-1AA36-0AB0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W
3VA1116-1AA36-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typeTerminal connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1116-1AA36-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1116-1AA36-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1116-1AA36-0AB0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1116-1AA36-0AB0 is a SENTRON switch disconnector in the 3VA1 IEC frame 160, rated for 160 A continuous current (Iu) across three poles. It is not a molded case circuit breaker — the description explicitly states 'without overload protection w/o short-circuit protection'. This is a pure disconnect and isolation device, not a protective device. The front terminal connection and IP40 front face suit panel-mount applications where you need a service disconnect or a load-break switch, not overcurrent coordination.

Rated continuous current Iu of 160 A means this switch disconnector can carry 160 A continuously without exceeding temperature limits — sized for a 160 A feeder or a large motor branch circuit. The 3-pole design handles three-phase AC loads up to 690 V AC (50/60 Hz) or DC loads up to 500 V DC. The maximum power loss of 38 W at rated current is a thermal budget figure: in a densely packed panel, that heat must be ventilated or the ambient temperature kept below the 70 °C maximum operating limit. The mechanical endurance of 15 000 operating cycles (latching endurance) is typical for a switch disconnector in this frame size — adequate for infrequent switching, not for daily cycling like a contactor.

Auxiliary contacts and integration

The 3VA1116-1AA36-0AB0 ships with 2 auxiliary switches (HP type) and 2 CO contacts for auxiliary circuits. That means you get two changeover contacts for status feedback — e.g., signaling the disconnect position to a PLC or interlocking a downstream contactor. The auxiliary contacts are built in, so no separate add-on block is needed for basic status indication. The optional motor drive (product extension optional) allows remote operation if the panel design requires it.

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a compact 3-pole footprint for a 160 A device. The front terminal connection (clamp-type) accepts standard copper busbars or cable lugs.

Frequently asked questions

Where can I buy 3VA1116-1AA36-0AB0 and get a price?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the depth of 3VA1116-1AA36-0AB0?

The listed depth is 70 mm, with a width of 76.2 mm and height of 130 mm.

Will 3VA1116-1AA36-0AB0 drop into a panel specified for 3VA1110-5ED36-0AC0 without rewiring?

Both parts share the same physical footprint (130 mm height, 76.2 mm width, 70 mm depth) and front terminal connection, so the mechanical fit and busbar alignment are identical. The 3VA1116-1AA36-0AB0 is a switch disconnector without overcurrent protection, while the 3VA1110-5ED36-0AC0 is a molded case circuit breaker with a TM210 release — the wiring to the main terminals is the same, but the protection function differs. If the panel design relies on the breaker's overcurrent protection, substituting a switch disconnector changes the protection scheme.