Siemens 3VA1116-1AA36-0CH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-1AA36-0CH0 SENTRON Switch Disconnector, 160

MPN3VA1116-1AA36-0CH0

Siemens SENTRON 3VA1 IEC frame 160, switch disconnector SD100, 3-pole, 160 A, without overload or short-circuit protection, undervoltage release 120-127V AC 50/60 Hz, 2 auxiliary switches HQ + 1 trip alarm switch HQ, front terminal connection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1116-1AA36-0CH0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design

Ratings

3VA1116-1AA36-0CH0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W

Construction & Connection

3VA1116-1AA36-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typeTerminal connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1116-1AA36-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1116-1AA36-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1116-1AA36-0CH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Switch disconnector for isolation duty — 160 A, no overcurrent protection

The Siemens SENTRON 3VA1116-1AA36-0CH0 is a 3-pole switch disconnector in MCCB-style construction, rated for 160 A continuous current (Iu) with a max AC operational voltage of 690 V and DC voltage of 500 V. It is designed purely for isolation and switching — no overload or short-circuit protection elements inside. This makes it the right choice for a load-break disconnect ahead of a downstream protection device, or as a manual disconnect switch in a distribution panel where the upstream breaker handles fault interruption.

Undervoltage release fitted — 120–127 V AC coil

This unit ships with an undervoltage release (UVR) wired for 120–127 V AC 50/60 Hz. When control voltage drops below the dropout threshold, the UVR trips the disconnector open — standard practice for motor feeder isolation where loss of control power should disconnect the load. The UVR does not include a leading contact, so the coil is energized continuously during normal operation. Verify the control circuit can supply the holding current before panel integration.

Auxiliary and alarm contacts — 2 HQ aux + 1 trip alarm

Three CO contacts are built in: two auxiliary switches (HQ — high-quality silver-alloy contacts for signal-level reliability) and one trip alarm switch that changes state when the disconnector opens via the UVR or manual handle. These give the PLC or BMS a positive feedback signal for switch position and fault status, without needing an external contact block.

Physical fit and panel integration

Footprint: 76.2 mm wide, 130 mm tall, 70 mm deep — standard 3-pole MCCB-style cutout. Front terminals accept clamp-type connections for the main circuit. IP40 on the front face means it's protected against tools and wires >1 mm, but not against water ingress; install inside a panel with a door. The 3VA1 frame accepts optional motor drive for remote switching.

MPN
3VA1116-1AA36-0CH0