Siemens 3VA1116-1AA42-0HC0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA1116-1AA42-0HC0 Switch Disconnector, 160 A, 4-Pol

MPN3VA1116-1AA42-0HC0

SENTRON 3VA1116-1AA42-0HC0, switch disconnector in MCCB design, IEC frame 160, 4-pole, SD100, In=160 A without overload or short-circuit protection, shunt trip (STL) 12-30 V DC; 24 V AC 50/60 Hz, 2 auxiliary switches HQ, busbar connection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1116-1AA42-0HC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1116-1AA42-0HC0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Power loss, max.38 W
3VA1116-1AA42-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1116-1AA42-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1116-1AA42-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1116-1AA42-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width101.6 mm
Depth70 mm

Product details

The SENTRON 3VA1116-1AA42-0HC0 is a 4-pole switch disconnector built in an MCCB (molded case circuit breaker) form factor, rated 160 A continuous at 40 °C with no derating needed up to 50 °C — it holds 160 A flat through that range, then tapers to 150 A at 70 °C. This is a pure disconnect — no overload or short-circuit protection inside. It is designed for manual load-break switching and isolation duty where the upstream protective device handles fault clearing. The shunt trip release (STL) allows remote tripping on a 12-30 V DC or 24 V AC control signal. Two built-in auxiliary switches (HQ type) provide status feedback for the open/closed position.

The optional motor drive (listed as optional extension) allows remote motorized operation if needed downstream.

MPN
3VA1116-1AA42-0HC0