Siemens 3VA1116-1AA42-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-1AA42-0KA0 Switch Disconnector, 160 A, 4-Pol

MPN3VA1116-1AA42-0KA0

Siemens SENTRON 3VA1116-1AA42-0KA0, switch disconnector in MCCB design, IEC frame 160, 4-pole, In=160 A, without overload or short-circuit protection, shunt trip (STL) 220-250 V DC / 208-277 V AC, busbar connection front terminal.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1116-1AA42-0KA0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design

Ratings

3VA1116-1AA42-0KA0 — Ratings
ParameterValue
Number of poles4
Power loss, max.38 W

Construction & Connection

3VA1116-1AA42-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1116-1AA42-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1116-1AA42-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1116-1AA42-0KA0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

What this part is and what it isn't

The Siemens 3VA1116-1AA42-0KA0 is a SENTRON switch disconnector in a molded-case switch (MCCB) form factor — it provides visible isolation and load-break capability but carries no overload or short-circuit protection. Rated continuous current Iu is 160 A on a 4-pole frame, with a rated insulation voltage Ui of 800 V and maximum operational voltage of 690 V AC 50/60 Hz or 600 V DC. The short-time withstand rating is 2 kA at both 1 s and 0.5 s, meaning it can pass fault current for that duration without damage while upstream protection clears the fault.

Shunt trip and auxiliary release

This variant ships with a shunt trip (STL) release designed for remote tripping: coil rated 220-250 V DC or 208-277 V AC. There is no undervoltage release, no auxiliary contact block, and no communication function — the only integrated release is the shunt trip. The front terminal accepts busbar connection for the main circuit; the optional motor drive is available as a field-installable accessory.

Panel fit and environment

Dimensions are 70 mm deep, 101.6 mm wide, and 130 mm high — the 4-pole width is wider than the standard 3-pole 76.2 mm footprint, so a panel designed for a 3-pole 3VA will need additional DIN rail space or a different gland plate cutout. Front protection class is IP40, suitable for enclosed panel mounting; operating temperature range is -25 °C to 70 °C, storage from -40 °C to 80 °C. Maximum power loss at rated current is 38 W.

How it differs from a circuit breaker sibling

The closest peer in the same frame size is the 3VA1110-5EE32-0JA0, a 3-pole 100 A molded-case circuit breaker with TM220 thermal-magnetic overcurrent release and a switching capacity class M (187 kA at 240 V). The key difference: the 3VA1116-1AA42-0KA0 is a switch disconnector with no overcurrent protection — it cannot clear a fault on its own and relies entirely on upstream protection. The 3VA1110-5EE32-0JA0 also uses lug terminals rather than busbar connection, and its 76.2 mm width means it occupies less DIN rail space. For a panel already wired for a 3-pole breaker, the 4-pole 3VA1116-1AA42-0KA0 will not drop in without rewiring and widening the mounting footprint.

Frequently asked questions

Will 3VA1116-1AA42-0KA0 drop into a panel specified around 3VA1110-5EE32-0JA0?

No — the 3VA1116-1AA42-0KA0 is 101.6 mm wide (4-pole) versus 76.2 mm for the 3-pole 3VA1110-5EE32-0JA0, so it requires additional DIN rail space and a different gland plate cutout. The wiring also differs: busbar connection on this part versus lug terminals on the breaker.

Where can I buy 3VA1116-1AA42-0KA0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — send the order code for a firm quote.