Skip to main content
Siemens 3VA1116-3EE36-0LC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-3EE36-0LC0 Circuit Breaker, 160A, 25kA @ 415

MPN3VA1116-3EE36-0LC0

Siemens 3VA1 IEC frame 160, 3-pole, breaking capacity class N, Icu=25kA @ 415V, In=160A, TM220 thermal-magnetic trip, Ir=112-160A, Ii=10xIn, clamp terminals, with 24V DC universal release and 2 auxiliary switch changeover contacts.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

It carries a breaking capacity class N with Icu=25kA at 415V, a rated current In=160A, adjustable overload protection Ir=112A to 160A, and fixed short-circuit protection Ii=10 x In. The unit includes a 24V DC universal release accessory for shunt or undervoltage trip applications, plus two auxiliary switch changeover contacts. Clamp terminals handle the power connections.

The TM220 thermal-magnetic trip gives you adjustable thermal overload (Ir) from 112A to 160A, so you dial in the exact motor or feeder protection without swapping trip units. Fixed magnetic pickup at 10x In (1600A) handles instantaneous short-circuit protection. The 24V DC universal release lets you integrate remote tripping from a safety PLC or emergency-stop circuit — it's a common add-on for coordinated shutdown schemes.

Clamp terminals accept copper or aluminum conductors — strip length and torque per the terminal marking. The 24V DC release and auxiliary switches wire into the control circuit separately from the power path; verify polarity on the release coil before energizing.

Frequently asked questions

What is the breaking capacity of this breaker?

The breaking capacity class N gives Icu=25kA at 415V AC — enough for most industrial distribution panels with moderate fault levels.

How is the overload protection adjusted?

The TM220 thermal-magnetic trip allows adjusting Ir from 112A to 160A via a dial on the front face. Short-circuit pickup Ii is fixed at 10x In (1600A).

What accessories are included with this order code?

This variant includes a 24V DC universal release (shunt/undervoltage trip) and two auxiliary switch changeover contacts, factory-fitted.

Where can I buy 3VA1116-3EE36-0LC0 and get a quote?

The part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for current pricing and availability — no minimum quantity required.

MPN