Skip to main content
Siemens 3VA1116-3EF32-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-3EF32-0AC0 SENTRON MCCB, 160 A, 3-Pole, 75.6

MPN3VA1116-3EF32-0AC0

Siemens SENTRON 3VA1116-3EF32-0AC0, Molded case circuit breaker, 3-pole, 160 A rated continuous current, TM240 thermal-magnetic release, breaking capacity 75.6 kA at 240 V, IP40 front, 2 auxiliary switches HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1116-3EF32-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1116-3EF32-0AC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C153.6 A
Current at 60 °C150.4 A
Current at 65 °C147.2 A
Current at 70 °C144 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V10.5 kA

Protection & Trip Unit

3VA1116-3EF32-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240

Construction & Connection

3VA1116-3EF32-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1116-3EF32-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1116-3EF32-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1116-3EF32-0AC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

160 A SENTRON MCCB with TM240 release

The Siemens SENTRON 3VA1116-3EF32-0AC0 is a 3-pole molded case circuit breaker rated for 160 A continuous current (Iu) at 40 °C ambient, with a TM240 thermal-magnetic overcurrent release. It is designed for line protection in distribution panels and motor control centers, carrying a breaking capacity of 75.6 kA at 240 V AC and 52.5 kA at 415 V AC — enough to handle high-fault utility feeds without cascading upstream. The TM240 release is a fixed thermal-magnetic trip unit; the thermal element adjusts via a front dial (tr max 1 s at rated current), while the magnetic pickup is factory-set. No undervoltage release, no shunt trip, no ground-fault module — this is a straight line-protection breaker for standard overcurrent and short-circuit duty. Rated insulation voltage is 800 V, with a mechanical endurance of 15,000 operations. The front face carries IP40 protection — suitable for enclosed panel mounting, not for washdown or outdoor exposure without an additional enclosure.

Breaking capacity across voltages

This breaker's interrupting rating drops as system voltage rises: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 10.5 kA at 690 V. For a 480 V panel fed from a transformer with a 40 kA available fault current, the 415 V figure (52.5 kA) is the relevant benchmark — it provides headroom. At 690 V the 10.5 kA rating limits use to lower-fault industrial grids. The 70 mm depth and 76.2 mm width fit standard SENTRON 3VA panel cutouts and busbar systems. Two auxiliary switches (HQ type) are built in for remote status indication — no add-on module required.

Thermal derating and operating range

Rated 160 A from 40 °C to 50 °C ambient. Above 50 °C the continuous current derates: 153.6 A at 55 °C, 150.4 A at 60 °C, 147.2 A at 65 °C, and 144 A at 70 °C. The operating ambient range is -25 °C to +70 °C; storage range is -40 °C to +80 °C. If the panel ambient runs above 50 °C, factor the derating into the load schedule.

Frequently asked questions

Where can I buy 3VA1116-3EF32-0AC0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA1116-3EF32-0AC0 at 415 V?

52.5 kA at 415 V AC.

Does this MCCB include a shunt trip or undervoltage release?

No — it ships without any auxiliary release; only the two built-in HQ auxiliary switches are included.

What is the rated continuous current of 3VA1116-3EF32-0AC0?

160 A at 40 °C ambient, with thermal derating above 50 °C.

MPN
3VA1116-3EF32-0AC0