Siemens 3VA1116-3EF32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-3EF32-0HC0 SENTRON MCCB, 160 A, 75.6 kA at 2

MPN3VA1116-3EF32-0HC0

Siemens SENTRON 3VA1116-3EF32-0HC0, 3-pole molded case circuit breaker, 160 A (40 °C), 75.6 kA at 240 V, line protection, shunt trip, 2 auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1116-3EF32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11163EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1116-3EF32-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.38 W

Protection & Trip Unit

3VA1116-3EF32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1116-3EF32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1116-3EF32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1116-3EF32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1116-3EF32-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What this MCCB is and where it fits

The Siemens 3VA1116-3EF32-0HC0 is a SENTRON molded case circuit breaker (MCCB) designed for line protection in distribution panels. Its 3-pole construction and 160 A rating at 40 °C suit it for main or feeder protection in commercial and industrial switchboards. The 75.6 kA breaking capacity at 240 V gives headroom for high-fault installations, while the 52.5 kA at 415 V covers common European 400 V grids. Insulation voltage is rated at 800 V, so it can sit in 690 V systems without derating the dielectric.

Breaking capacity and thermal derating

Breaking capacity drops from 75.6 kA at 240 V to 52.5 kA at 415 V, then to 32 kA at 440 V, and further to 11.9 kA at 500 V and 690 V. That means on a 400 V system this MCCB handles 52.5 kA prospective fault current — enough for most secondary substations. Thermal derating is mild: 160 A holds from 40 °C to 50 °C, then steps down to 158 A at 55 °C, 155 A at 60 °C, 153 A at 65 °C, and 150 A at 70 °C. So in a warm enclosure at 55 °C you lose only 2 A.

Panel fit and wiring

Dimensions are 130 mm high, 76.2 mm wide, 70 mm deep. The 76.2 mm width is a standard 3-pole MCCB footprint — it fits a 3-module wide DIN-rail or panel-mount cutout. Depth of 70 mm leaves clearance for rear-connected busbars. The shunt trip and auxiliary switches are factory-installed; no field wiring of the release is needed.

Frequently asked questions

How do I get current pricing and availability for 3VA1116-3EF32-0HC0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is the closest functional second-source to 3VA1116-3EF32-0HC0?

The 3VA1110-5EE32-0LC0 and 3VA1110-5EF32-0AM0 are lower-current siblings in the same SENTRON 3VA platform. They share the same frame size and mounting footprint but have different trip ratings and breaking capacities. The 3VA1116-3EF32-0HC0 is the 160 A variant with shunt trip and two auxiliary switches; a direct swap without rewiring is only possible if the replacement has the same accessories and rating.

Will 3VA1116-3EF32-0HC0 drop into a panel specified around 3VA1110-5EE32-0LC0 without rewiring?

The 3VA1116-3EF32-0HC0 shares the same 3-pole frame and 76.2 mm width, so it fits the same cutout and busbar spacing. However, the 160 A rating requires larger cable lugs and the shunt trip wiring differs from a standard thermal-magnetic release. Verify the existing busbar ampacity and accessory wiring before swapping.

What compliance documentation does this brand provide for 3VA1116-3EF32-0HC0?

Siemens provides RoHS, REACH, UL, and IEC declarations for the SENTRON 3VA series. These are available as PDFs through the manufacturer's support portal or upon request from the distributor.

MPN
3VA1116-3EF32-0HC0