Skip to main content
Siemens 3VA1116-3EF32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-3EF32-0JA0 SENTRON MCCB, 160 A, 3-Pole, 75.6

MPN3VA1116-3EF32-0JA0

Siemens SENTRON 3VA1116-3EF32-0JA0, molded case circuit breaker, 3-pole, 160 A at 40 °C, breaking capacity 75.6 kA at 240 V AC, with TM240 thermal-magnetic overcurrent release and shunt trip (STL).

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1116-3EF32-0JA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11163EF320AA0

Ratings

3VA1116-3EF32-0JA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.38 W

Protection & Trip Unit

3VA1116-3EF32-0JA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1116-3EF32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1116-3EF32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1116-3EF32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1116-3EF32-0JA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What it is and what it does

The Siemens 3VA1116-3EF32-0JA0 is a SENTRON molded case circuit breaker (MCCB) designed for line protection in distribution panels. It carries a 160 A continuous rating at 40 °C ambient, with a 3-pole configuration and a TM240 thermal-magnetic overcurrent release that provides both overload and short-circuit protection in a single unit. Breaking capacity is 75.6 kA at 240 V AC, 52.5 kA at 415 V, and 32 kA at 440 V — figures that determine whether this breaker clears a fault without upstream damage in your specific system voltage. At 500 V and 690 V the rating drops to 11.9 kA, so verify your available fault current at the point of installation. The breaker includes a shunt trip (STL) auxiliary release for remote tripping, and the insulation voltage is rated 800 V. Power loss at full load is 38 W maximum, which matters for enclosure thermal calculations in a crowded panel.

Panel fit and integration

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a standard footprint that fits most DIN-rail or panel-mount MCCB enclosures. The 3-pole design with shunt trip means you need to account for the auxiliary wiring when laying out the panel; the undervoltage release is not fitted on this variant.

Frequently asked questions

How do I get current pricing and availability for 3VA1116-3EF32-0JA0?

Submit an RFQ through this listing. The part is sourced to order; pricing and stock levels are confirmed at quote time and vary with market conditions.

What is the breaking capacity of this MCCB at 415 V?

52.5 kA at 415 V AC. At 240 V it is 75.6 kA, at 440 V it is 32 kA, and at 500 V or 690 V it is 11.9 kA.

What compliance documentation is available for 3VA1116-3EF32-0JA0?

As a SENTRON MCCB, it carries the standard Siemens compliance documentation including RoHS and REACH declarations, and is designed to meet IEC 60947-2 and UL 489 requirements. Specific certificates can be requested with the RFQ.

MPN
3VA1116-3EF32-0JA0