Specifications

Identification

3VA1116-3GF42-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA11163GF420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1116-3GF42-0AH0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.38 W

Protection & Trip Unit

3VA1116-3GF42-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout

Construction & Connection

3VA1116-3GF42-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1116-3GF42-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1116-3GF42-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1116-3GF42-0AH0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

What this MCCB carries

The Siemens SENTRON 3VA1116-3GF42-0AH0 is a 4-pole molded case circuit breaker rated for line protection. It carries a TM240 thermal-magnetic overcurrent release and is rated 160 A continuous at 40 °C, with a thermal derating curve that holds 160 A up to 50 °C, then steps down to 158 A at 55 °C, 155 A at 60 °C, 153 A at 65 °C, and 150 A at 70 °C — so in a warm panel you lose less than 7 % of the rating at the top end. Rated insulation voltage is 800 V, so it's comfortable on 690 V systems. The front carries IP40 protection — fine for a clean indoor panel, not for washdown areas.

Auxiliaries and dimensions

Factory-fitted with 2 auxiliary switches plus 1 trip alarm switch (HQ configuration). No undervoltage release, no ground-fault monitoring, no communication module — this is a bare breaker for a standard distribution board. Power loss is 38 W maximum at rated load. Footprint is 101.6 mm wide by 130 mm tall by 70 mm deep — about 4 by 5.12 by 2.76 inches. That's the standard 4-pole SENTRON 3VA frame size; it drops into the same mounting cutout as other 3VA breakers of this pole count. Trip indicator is present on the front, so you can spot a tripped breaker without opening the door.