Skip to main content
Siemens 3VA1116-4ED12-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-4ED12-0AA0 SENTRON MCCB, 1-pole 160 A, TM210

MPN3VA1116-4ED12-0AA0
Active

Siemens SENTRON 3VA1116-4ED12-0AA0, 1-pole molded case circuit breaker, 160 A, TM210 thermal-magnetic release, LI protection, 75.6 kA at 240 V, 9 kA at 415 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1116-4ED12-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA1116-4ED12-0AA0 — Ratings
ParameterValue
Number of poles1
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Switching capacity classS
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V9 kA
Power loss, max.12.67 W

Protection & Trip Unit

3VA1116-4ED12-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout

Construction & Connection

3VA1116-4ED12-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1116-4ED12-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0

Environmental

3VA1116-4ED12-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1116-4ED12-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width25.4 mm
Depth70 mm
Height (in)5.12 in
Width (in)1 in
Depth (in)2.76 in

Product details

The Siemens 3VA1116-4ED12-0AA0 is a SENTRON 1-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current Iu of 160 A at 45 °C and 50 °C, derating to 150 A at 70 °C. The TM210 thermal-magnetic release provides LI (long-time and instantaneous) protection with a fixed instantaneous pickup Ii of 1600 A. Breaking capacity reaches 75.6 kA at 240 V AC and 9 kA at 415 V AC — the 415 V figure is the one that governs most industrial 400 V distribution panels.

Thermal derating and panel fit

At 55 °C the breaker carries 158 A, at 60 °C it drops to 155 A, and at 65 °C to 153 A — a derating curve of roughly 1 A per 5 °C above 50 °C. For a panel running at 55 °C ambient, the effective capacity is 158 A, not the nameplate 160 A. The 25.4 mm width (1 inch) per pole means a 1-pole unit occupies a single 1-inch slot on the DIN rail; depth is 70 mm and height 130 mm. Front IP40 protects against tools and wires but not washdown — keep it inside a sealed enclosure if the environment is wet.

Frequently asked questions

What is the breaking capacity of 3VA1116-4ED12-0AA0 at 240 V and 415 V?

At 240 V AC the breaking capacity is 75.6 kA; at 415 V AC it is 9 kA. The 415 V figure is the relevant one for most 400 V industrial distribution panels.

What is the thermal derating for 3VA1116-4ED12-0AA0 above 50 °C?

At 55 °C the continuous rating is 158 A, at 60 °C it is 155 A, at 65 °C it is 153 A, and at 70 °C it is 150 A. The derating is roughly 1 A per 5 °C above 50 °C.

Where can I buy 3VA1116-4ED12-0AA0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 3VA1116-4ED12-0AA0 drop into a panel specified around 3VA1112-5EE32-0AA0 without rewiring?

Both are 1-pole SENTRON MCCBs with the same 25.4 mm width per pole, so the mechanical footprint is identical. However, the 3VA1116-4ED12-0AA0 is rated 160 A with a TM210 release, while the 3VA1112-5EE32-0AA0 is a different rating — verify the load current and release settings before swapping.

MPN
3VA1116-4ED12-0AA0