Siemens 3VA1116-4ED26-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-4ED26-0AC0 160A Circuit Breaker, 36kA @ 415V

MPN3VA1116-4ED26-0AC0

Siemens 3VA1 series, IEC frame 160, breaking capacity class S, 2-pole, 160A, Icu=36kA @ 415V, TM210 line protection, clamp connection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What this 3VA1 breaker delivers

The Siemens 3VA1116-4ED26-0AC0 is a 2-pole IEC frame 160 molded case circuit breaker rated for 160 A continuous, with a 36 kA interrupting capacity at 415 V AC (breaking capacity class S). That Icu figure means it can safely clear a bolted fault up to 36 kA without welding its contacts or rupturing the arc chamber — a critical spec for panel builders sizing upstream protection on a distribution board or motor control center. Overload protection is fixed at Ir = 160 A via the TM210 thermal-magnetic trip unit; short-circuit pickup is fixed at Ii = 10 × In (1600 A). No field-adjustable dials on the trip curve — what you order is what protects the feeder. The clamp connection terminals accept standard copper busbar or cable lugs, which simplifies panel wiring compared to screw-clamp alternatives.

Panel integration note

The 3VA1 frame 160 mounts on a DIN rail or directly to a backplate via the standard screw-fixing points. At 160 A fixed Ir, consider the thermal derating when packing multiple breakers into a closed enclosure — Siemens publishes a derating curve for the 3VA1 series that accounts for ambient temperature and adjacent-device heat rise. The integrated auxiliary switch changeover (2 × changeover contacts) is wired at the factory, so no add-on module is needed for remote status feedback.

Frequently asked questions

What is the interrupting rating of this breaker?

The 3VA1116-4ED26-0AC0 has a rated ultimate breaking capacity (Icu) of 36 kA at 415 V AC, which is the S (standard) class within the 3VA1 IEC frame 160 family.

Where can I buy 3VA1116-4ED26-0AC0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the overload protection setting on this breaker?

Overload protection is fixed at Ir = 160 A (non-adjustable) via the TM210 thermal-magnetic trip unit, with short-circuit pickup fixed at Ii = 10 × In (1600 A).

MPN
3VA1116-4ED26-0AC0