Skip to main content
Siemens 3VA1116-4ED32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-4ED32-0AA0 SENTRON MCCB, 160A, 3-Pole, 121kA

MPN3VA1116-4ED32-0AA0
Active

Siemens SENTRON 3VA1116-4ED32-0AA0, molded case circuit breaker, 3 poles, 160 A rated current, 121 kA breaking capacity at 240 V AC, TM210 overcurrent release, IP40 front protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1116-4ED32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1116-4ED32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.38 W
3VA1116-4ED32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1116-4ED32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1116-4ED32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1116-4ED32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1116-4ED32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The 3VA1116-4ED32-0AA0: Breaking capacity drops as voltage climbs: 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V. That 11.9 kA floor at 690 V is the real constraint if you're running a 690 V distribution bus — verify your available fault current at that voltage, not the 240 V headline. The TM210 release holds 160 A flat from 40 °C through 50 °C, then derates to 150 A at 70 °C. In a hot panel — say next to a drive or transformer — use the 70 °C column, not the 40 °C rating.

Dimensions are 76.2 mm wide, 130 mm tall, 70 mm deep — three 18 mm pole spaces, so it fits a standard DIN-rail or panel-mount footprint without surprises.

Frequently asked questions

Where can I buy 3VA1116-4ED32-0AA0 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA1116-4ED32-0AA0 at different voltages?

121 kA at 240 V AC, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V.

What are the physical dimensions of this MCCB?

76.2 mm wide, 130 mm tall, 70 mm deep — three 18 mm pole spaces.

Will 3VA1116-4ED32-0AA0 drop into a panel specified for 3VA1112-5EE32-0AA0?

Both are 3-pole SENTRON MCCBs in the same 76.2 mm width footprint, so mechanical fit is the same. The key difference is the 160 A rating on this one versus the lower-rated sibling — verify your load current and the TM release curve before swapping.

MPN
3VA1116-4ED32-0AA0