Skip to main content
Siemens 3VA1116-4EF32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-4EF32-0DH0 SENTRON MCCB, 160A, 3-Pole, 121kA

MPN3VA1116-4EF32-0DH0

Siemens SENTRON 3VA1116-4EF32-0DH0, molded case circuit breaker, 3-pole, 160 A (at 40 °C), breaking capacity 121 kA at 240 V AC, line protection, undervoltage release, 2 aux + 1 trip alarm switch.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1116-4EF32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11164EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1116-4EF32-0DH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.40.5 W

Protection & Trip Unit

3VA1116-4EF32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1116-4EF32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1116-4EF32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1116-4EF32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1116-4EF32-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Siemens 3VA1116-4EF32-0DH0 — SENTRON MCCB, 160 A, 3-Pole, Line Protection

The Siemens 3VA1116-4EF32-0DH0 is a SENTRON molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current of 160 A at 40 °C (derated to 150 A at 70 °C per the thermal curve). It is a three-pole unit with a rated insulation voltage of 800 V, and its maximum breaking capacity reaches 121 kA at 240 V AC — sufficient for high-fault utility feeds or transformer secondaries where SCCR headroom is critical. This breaker includes an undervoltage release (UVR) as the auxiliary release type, plus two auxiliary switches and one trip alarm switch (HQ configuration) — enough for remote status indication and undervoltage trip coordination in a safety circuit.

Breaking Capacity Across Voltages — Selectivity Planning

The 3VA1116-4EF32-0DH0 delivers 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V. These figures define the maximum prospective fault current the breaker can safely interrupt at each voltage level — essential for coordination studies and ensuring the MCCB is not applied beyond its interrupting rating on a high-fault bus.

Thermal Derating and Ambient Operating Range

Rated 160 A continuously at 40 °C through 50 °C, the breaker begins to derate above 55 °C: 158 A at 55 °C, 155 A at 60 °C, 153 A at 65 °C, and 150 A at 70 °C. The operating ambient range is -25 °C to +70 °C, with storage from -40 °C to +80 °C. Maximum power loss is 40.5 W.

Dimensions and Panel Integration

The breaker measures 130 mm high, 76.2 mm wide, and 70 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures without requiring backpan modifications. The 70 mm depth is the dimension from the mounting surface to the front of the breaker, which governs the minimum enclosure depth.

Frequently asked questions

Where can I buy 3VA1116-4EF32-0DH0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of 3VA1116-4EF32-0DH0 at 240 V?

The maximum breaking capacity is 121 kA at 240 V AC.

Does 3VA1116-4EF32-0DH0 include an undervoltage release?

Yes, it includes an undervoltage release (UVR) as the auxiliary release type, plus two auxiliary switches and one trip alarm switch.

What is the rated current of 3VA1116-4EF32-0DH0 at 40 °C?

The rated continuous current is 160 A at 40 °C, derating to 150 A at 70 °C.

MPN
3VA1116-4EF32-0DH0