Skip to main content
Siemens 3VA1116-4EF36-0CH0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA1116-4EF36-0CH0 MCCB, 160A, 3-Pole, 121kA

MPN3VA1116-4EF36-0CH0

Siemens SENTRON 3VA series, molded case circuit breaker (MCCB), 3VA1116-4EF36-0CH0, 3-pole, 160 A rated at 40 °C, 121 kA breaking capacity at 240 VAC, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1116-4EF36-0CH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11164EF360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1116-4EF36-0CH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.40.5 W
3VA1116-4EF36-0CH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1116-4EF36-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1116-4EF36-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1116-4EF36-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1116-4EF36-0CH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Breaking capacity reaches 121 kA at 240 VAC, dropping to 75.6 kA at 415 V and 52.5 kA at 440 V, which covers most industrial distribution panels without needing a current-limiting upstream device. No communication module is fitted — this is a standalone line-protection device, not a networked power manager.

The 3VA1116-4EF36-0CH0 measures 76.2 mm wide, 130 mm tall, and 70 mm deep. A trip indicator is present, so a quick visual scan of the panel face tells you which breaker cleared the fault.

Frequently asked questions

Where can I buy 3VA1116-4EF36-0CH0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at that time.

Will 3VA1116-4EF36-0CH0 drop into a panel specified around 3VA1110-5ED36-0AC0 without rewiring?

The 3VA1116-4EF36-0CH0 shares the same 3-pole SENTRON 3VA platform and the same 76.2 mm width as the 3VA1110-5ED36-0AC0, so it fits the same panel cutout and busbar spacing. However, the 160 A rating is higher than the 100 A class of the 3VA1110, so verify that upstream and downstream conductors and devices are rated for the higher continuous current before swapping.

What is the breaking capacity of this MCCB at 415 V?

At 415 VAC the 3VA1116-4EF36-0CH0 delivers 75.6 kA breaking capacity, which covers most industrial distribution fault levels without requiring a current-limiting upstream breaker.

MPN
3VA1116-4EF36-0CH0