Skip to main content
Siemens 3VA1116-4EF36-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-4EF36-0HC0 SENTRON MCCB, 160A, 3-Pole, 121kA

MPN3VA1116-4EF36-0HC0

Siemens SENTRON 3VA1116-4EF36-0HC0, molded case circuit breaker, 3-pole, 160 A rated, 121 kA interrupting capacity at 240 V AC, line protection design, with shunt trip and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1116-4EF36-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11164EF360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1116-4EF36-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.38 W
3VA1116-4EF36-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1116-4EF36-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1116-4EF36-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1116-4EF36-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1116-4EF36-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

It is a current-production part (lifecycle stage: current). Interrupting capacity runs 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V — so the SCCR headroom is highest on lower-voltage services and drops off sharply above 500 V.

Thermal derating — what the 160 A rating actually means in a warm panel

Above that it steps down: 158 A at 55 °C, 155 A at 60 °C, 153 A at 65 °C, and 150 A at 70 °C.

Built-in accessories — shunt trip and auxiliary switches

No undervoltage release or ground-fault module is included. The basic switch module is order code 3VA11164EF360AA0 — useful if you ever need to order the bare switch separately for a replacement.

Panel footprint and mounting

Frequently asked questions

Where can I buy 3VA1116-4EF36-0HC0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — no stock count or price is published here.

What is the interrupting capacity of 3VA1116-4EF36-0HC0 at different voltages?

121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V. The SCCR is highest on 240 V services and derates significantly above 500 V.

Does 3VA1116-4EF36-0HC0 include a shunt trip or auxiliary contacts?

Yes, it ships with a shunt trip (STL) for remote tripping and two HQ auxiliary switches for status indication. No undervoltage release or ground-fault module is included.

MPN