Skip to main content
Siemens 3VA1116-4EF36-0KH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-4EF36-0KH0 SENTRON MCCB, 160 A, 3-Pole, 121

MPN3VA1116-4EF36-0KH0

Siemens SENTRON 3VA series, molded case circuit breaker (MCCB), 3VA1116-4EF36-0KH0, 160 A, 3-pole, 121 kA interrupting rating at 240 VAC, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1116-4EF36-0KH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11164EF360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1116-4EF36-0KH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.38 W

Protection & Trip Unit

3VA1116-4EF36-0KH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1116-4EF36-0KH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1116-4EF36-0KH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1116-4EF36-0KH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1116-4EF36-0KH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What the ratings mean for fit

The Siemens 3VA1116-4EF36-0KH0 is a SENTRON-series molded case circuit breaker (MCCB) for line protection. Its 160 A continuous rating holds across the 40 °C to 50 °C band without derating, then steps down to 150 A at 70 °C — so in a warm panel the full 160 A is available as long as ambient stays under 50 °C. The 121 kA breaking capacity at 240 VAC is the figure that governs fault interruption on a 240 V distribution bus; at 415 V it still clears 75.6 kA, and at 690 V the rating drops to 11.9 kA. That tells you the breaker is sized for high-fault commercial or industrial switchboards on 240/415 V services, not for 690 V drives.

Current production — no LTB concern

The lifecycle stage is marked current, meaning Siemens still manufactures this exact order code. No last-time-buy notice, no successor assigned.

Panel fit and auxiliary options

Three-pole, 70 mm deep, 76.2 mm wide, 130 mm tall. Mounts into the standard MCCB footprint on a DIN rail or panel-mount base. Ships with a shunt trip (STL) release and two auxiliary switches plus one trip alarm switch (HQ). Rated insulation voltage is 800 V.

MPN
3VA1116-4EF36-0KH0