Siemens 3VA1116-4FD42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-4FD42-0AA0 SENTRON MCCB, 80 A, 4-Pole, TM210

MPN3VA1116-4FD42-0AA0
Active

Siemens SENTRON 3VA1116-4FD42-0AA0, molded case circuit breaker (MCCB), 80 A, 4-pole, TM210 thermal-magnetic release, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1116-4FD42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA1116-4FD42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.38 W

Protection & Trip Unit

3VA1116-4FD42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1116-4FD42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1116-4FD42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1116-4FD42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1116-4FD42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

Integrator note: 80 A MCCB with TM210 release

The Siemens 3VA1116-4FD42-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated at 80 A continuous, configured as a 4-pole unit with a TM210 thermal-magnetic overcurrent release. The TM210 designation indicates a fixed thermal pickup and a magnetic trip threshold set at 10× the rated current (800 A magnetic instantaneous), which governs short-circuit protection for line-feeder and distribution applications. Breaking capacity is specified across multiple voltage levels: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V. These figures define the maximum fault current the breaker can safely interrupt at each voltage — essential for verifying SCCR coordination with upstream gear in a panel schedule. Thermal derating is published across a 40 °C to 70 °C ambient band: the breaker carries 160 A continuously at 40 °C, 45 °C, and 50 °C, then derates to 158 A at 55 °C, 155 A at 60 °C, 153 A at 65 °C, and 150 A at 70 °C. For a panel enclosure running at 55 °C ambient, the effective continuous rating drops to 158 A — a factor to confirm against the connected load before committing the BOM line.

Dimensions and panel fit

Physical footprint: 130 mm height, 101.6 mm width, 70 mm depth. The 4-pole width (101.6 mm / 4 in) is standard for a 4-pole MCCB in this frame size; verify the DIN-rail or mounting-plate spacing in the existing panel if replacing a different make. IP40 on the front face means the breaker is protected against solid objects >1 mm but not against water ingress — suitable for indoor panel mounting, not washdown zones.

Lifecycle and compliance posture

Rated insulation voltage is 800 V, and maximum power loss is 38 W. The breaker is designed for line protection (not motor or generator protection), with no undervoltage release, no trip indicator, and no communication function. These omissions are by design for a basic thermal-magnetic feeder breaker — the absence of a trip indicator means fault-event diagnostics rely on external metering or a separate indication auxiliary.

Frequently asked questions

How do I get current pricing and availability for 3VA1116-4FD42-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time commitment.

What is 3VA1116-4FD42-0AA0's listed depth?

The depth is 70 mm (2.76 in). Combined with a height of 130 mm and width of 101.6 mm, the breaker fits standard 4-pole MCCB panel cutouts in the SENTRON 3VA frame.

What compliance documentation does this brand provide for 3VA1116-4FD42-0AA0?

As a current-production Siemens SENTRON MCCB, the 3VA1116-4FD42-0AA0 is supported by the standard Siemens documentation package including a declaration of conformity, IEC/EN 60947-2 test certificates, and material compliance declarations (RoHS, REACH). Specific document downloads are available through the Siemens Industry Online Support portal using this order code.

MPN
3VA1116-4FD42-0AA0