Skip to main content
Siemens 3VA1116-5ED32-0DC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-5ED32-0DC0 SENTRON MCCB, 160 A, 187 kA at 24

MPN3VA1116-5ED32-0DC0

Siemens SENTRON 3VA1116-5ED32-0DC0, Molded case circuit breaker, 3-pole, 160 A, TM210 thermal-magnetic release, 187 kA interrupting at 240 V, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1116-5ED32-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1116-5ED32-0DC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C153.6 A
Current at 60 °C150.4 A
Current at 65 °C147.2 A
Current at 70 °C144 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA
3VA1116-5ED32-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1116-5ED32-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1116-5ED32-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1116-5ED32-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1116-5ED32-0DC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

SENTRON 3VA1116-5ED32-0DC0 — 160 A MCCB with TM210 Release

It delivers 187 kA interrupting capacity at 240 V, 121 kA at 415 V, and 75.6 kA at 440 V — numbers that govern the available fault current the breaker can safely clear without upstream coordination failure. The TM210 release provides thermal protection for overloads and magnetic instantaneous trip for short circuits — a standard choice for feeder and branch circuit protection in commercial and industrial switchboards.

Interrupting Capacity and Thermal Derating

At 690 V the interrupting rating drops to 17 kA — verify system fault levels if deploying on 600 V class equipment. The 160 A rating holds flat from 40 °C through 50 °C, then derates to 153.6 A at 55 °C, 150.4 A at 60 °C, 147.2 A at 65 °C, and 144 A at 70 °C.

Panel Fit and Lifecycle

Footprint is 76.2 mm wide × 130 mm tall × 70 mm deep — standard 3-pole MCCB envelope for DIN-rail or panel-mount installation.

Frequently asked questions

What are the interrupting ratings for 3VA1116-5ED32-0DC0?

187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V. These values govern the maximum fault current the breaker can safely clear at each voltage level.

How does temperature affect the 160 A rating on this MCCB?

The 160 A rating holds from 40 °C to 50 °C, then derates to 153.6 A at 55 °C, 150.4 A at 60 °C, 147.2 A at 65 °C, and 144 A at 70 °C. Panel ambient temperature inside the enclosure determines actual continuous current capacity.

Where can I buy 3VA1116-5ED32-0DC0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

Does 3VA1116-5ED32-0DC0 include auxiliary contacts or an undervoltage release?

Yes, it ships with 2 HQ auxiliary switches and an integrated undervoltage release (UVR) as standard equipment.

MPN
3VA1116-5ED32-0DC0