Skip to main content
Siemens 3VA1116-5EE32-0DC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-5EE32-0DC0 SENTRON MCCB, 160 A, 187 kA at 24

MPN3VA1116-5EE32-0DC0

Siemens SENTRON 3VA1116-5EE32-0DC0, molded case circuit breaker, 3-pole, 160 A rated continuous current Iu, 187 kA at 240 V, TM220 overcurrent release, undervoltage release, 2 auxiliary switches HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1116-5EE32-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1116-5EE32-0DC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C153.6 A
Current at 60 °C150.4 A
Current at 65 °C147.2 A
Current at 70 °C144 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA

Protection & Trip Unit

3VA1116-5EE32-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220

Construction & Connection

3VA1116-5EE32-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1116-5EE32-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1116-5EE32-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1116-5EE32-0DC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

MCCB with high interrupting capacity for line protection

The Siemens SENTRON 3VA1116-5EE32-0DC0 is a 3-pole molded case circuit breaker rated for line protection, carrying a continuous current Iu of 160 A. Its interrupting capacity reaches 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V — figures that govern its ability to clear a fault without upstream devices needing to trip. The TM220 thermal-magnetic overcurrent release handles the overload and short-circuit curves; there is no electronic trip unit, no communication function, and no phase failure detection built in. An undervoltage release (UVR) is fitted as the auxiliary release, and the auxiliary contact configuration is 2 HQ (high-availability) switches.

Thermal derating and panel fit

The 160 A rating holds flat from 40 °C through 50 °C. Above that it derates per the datasheet curve: 153.6 A at 55 °C, 150.4 A at 60 °C, 147.2 A at 65 °C, and 144 A at 70 °C. If the panel ambient runs at 60 °C, the usable current is 150.4 A — not the nameplate 160 A. The enclosure footprint is 130 mm high, 76.2 mm wide, and 70 mm deep. Front protection is IP40; the body is not sealed for washdown. The DIN EN 81346-2 reference code is Q, consistent with circuit-breaker function in a panel schematic.

Frequently asked questions

Where can I buy 3VA1116-5EE32-0DC0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

Does this breaker include a trip indicator or communication?

No. The trip indicator is not fitted, and there is no communication function or phase failure detection. The overcurrent release is the TM220 thermal-magnetic type.

MPN
3VA1116-5EE32-0DC0