Siemens 3VA1116-5EE32-0KA0 SENTRON MCCB, 160 A, 3-Pole, TM22

MPN3VA1116-5EE32-0KA0

Siemens SENTRON 3VA1116-5EE32-0KA0, molded case circuit breaker, 160 A, 3-pole, TM220 overcurrent release, 187 kA at 240 V, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1116-5EE32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1116-5EE32-0KA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C153.6 A
Current at 60 °C150.4 A
Current at 65 °C147.2 A
Current at 70 °C144 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA
3VA1116-5EE32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
3VA1116-5EE32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1116-5EE32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1116-5EE32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1116-5EE32-0KA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

MCCB with 160 A continuous rating and 187 kA interrupting capacity

The Siemens 3VA1116-5EE32-0KA0 is a SENTRON molded case circuit breaker rated for 160 A continuous current (Iu) across a 40 °C to 50 °C ambient range, with a 187 kA interrupting capacity at 240 V — enough to handle high-fault utility feeds or transformer secondaries without cascading upstream. Its 3-pole construction and TM220 thermal-magnetic release provide standard line protection for distribution panels, motor control centers, and feeder circuits.

No auxiliary contacts or communication module are included.

Frequently asked questions

Does 3VA1116-5EE32-0KA0 include a shunt trip?

Yes, it is equipped with a shunt trip (STL) release, factory-installed as order code 3VA9688-0BL33.

MPN