The Siemens SENTRON 3VA1116-5EF32-0LC0 is a 3-pole molded case circuit breaker (MCCB) rated for continuous current up to 160 A across an ambient range of 40 °C to 50 °C, with minimal derating to 150 A at 70 °C. This means it handles full-rated load in a warm enclosure without oversizing.

Siemens 3VA1116-5EF32-0LC0 SENTRON MCCB, 160 A, 3-Pole, 187
MPN3VA1116-5EF32-0LC0
Siemens SENTRON 3VA1116-5EF32-0LC0, molded case circuit breaker, 3-pole, 160 A, TM240 trip, 187 kA at 240 V, universal release, 2 auxiliary switches HQ.
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Product designation | Molded case circuit breaker |
| Brand / range | SENTRON |
| Basic switch (supplied) ref. | 3VA11165EF320AA0 |
| Integrated auxiliary / alarm switch ref. | 3VA9988-0AA12 |
| Parameter | Value |
|---|---|
| Number of poles | 3 |
| Rated operational voltage Ue (AC) | 690 V |
| Rated insulation voltage Ui | 800 V |
| Current at 40 °C | 160 A |
| Current at 45 °C | 160 A |
| Current at 50 °C | 160 A |
| Current at 55 °C | 158 A |
| Current at 60 °C | 155 A |
| Current at 65 °C | 153 A |
| Current at 70 °C | 150 A |
| Switching capacity class | M |
| Breaking capacity at 240 V | 187 kA |
| Breaking capacity at 415 V | 121 kA |
| Breaking capacity at 440 V | 75.6 kA |
| Breaking capacity at 500 V | 17 kA |
| Breaking capacity at 690 V | 17 kA |
| Power loss, max. | 40.5 W |
| Parameter | Value |
|---|---|
| Overcurrent release (trip unit) type | TM240 |
| Overcurrent protection function | LI |
| Ground-fault monitoring | Without |
| Grounding protection function | No |
| Parameter | Value |
|---|---|
| Main circuit connection type | nut keeper kit on both ends |
| Main circuit connector arrangement | Front terminal |
| Protection class (IP), front | IP40 |
| Parameter | Value |
|---|---|
| Undervoltage release | Yes |
| Voltage trigger | Yes |
| Trip indicator | No |
| Communication function | No |
| Measurement function | No |
| Motor drive option | Yes |
| Auxiliary CO contacts | 2 |
| Parameter | Value |
|---|---|
| Operating temperature, max. | 70 °C |
| Operating temperature, min. | -25 °C |
| Storage temperature, max. | 80 °C |
| Storage temperature, min. | -40 °C |
| Parameter | Value |
|---|---|
| Mechanical service life (operating cycles), typ. | 20 000 |
| Height | 130 mm |
| Width | 76.2 mm |
| Depth | 70 mm |
| Height (in) | 5.12 in |
| Width (in) | 3 in |
| Depth (in) | 2.76 in |
Product details
Frequently asked questions
Does this breaker include auxiliary contacts and an undervoltage release?
Yes. It comes with two HQ auxiliary switches and an undervoltage release integrated — no separate order needed for basic remote status and shunt-trip capability.
MPN
3VA1116-5EF32-0LC0