Siemens 3VA1116-6ED36-0KC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-6ED36-0KC0 Circuit Breaker, 160A, 70kA @ 415

MPN3VA1116-6ED36-0KC0

Siemens 3VA1 series, IEC frame 160, breaking capacity class H, 3-pole, line protection TM210, In=160A, Icu=70kA @ 415V, shunt trip 220-250V DC / 208-277V AC, 2 auxiliary switches HQ, clamp connection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

The Siemens 3VA1116-6ED36-0KC0 is a 3VA1 IEC frame 160 molded case circuit breaker with a 160 A fixed rating and a 70 kA breaking capacity at 415 V (class H). It is a 3-pole unit configured for line protection with a TM210 thermal-magnetic trip unit — the overload protection is fixed at Ir = 160 A, and the short-circuit protection is fixed at Ii = 10 × In. The breaker includes an integrated shunt trip (STL) rated for 220–250 V DC or 208–277 V AC, plus two HQ auxiliary switches. Connection is via clamp terminals.

What the ratings mean for panel fit

The 70 kA Icu at 415 V puts this breaker in the high-breaking-capacity class (H) for the 3VA1 frame. That SCCR matters when coordinating downstream with a transformer or a large motor branch circuit where fault current can exceed 50 kA — it avoids cascading failure upstream. The TM210 trip unit means the thermal element is sized for a 160 A continuous load; there is no adjustment range on Ir or Ii, so the breaker is a fixed-drop-in replacement for a 160 A branch. The shunt trip allows remote tripping from an E-stop or safety PLC, common in conveyor or pump panel layouts.

Deployment context

This breaker mounts on a DIN rail or directly to a backplate in an IEC-style panel. The clamp connection accepts copper or aluminum conductors without lug kits, saving install time. The two HQ auxiliary switches provide independent status feedback for the open/closed position — one can feed a PLC input for remote indication, the other can lock out a contactor coil.

Frequently asked questions

What are the key ratings for this circuit breaker?

It is a 3-pole IEC frame 160 breaker with a 160 A fixed rating, 70 kA breaking capacity at 415 V (class H), TM210 thermal-magnetic trip unit with Ir=160 A fixed and Ii=10 × In, a shunt trip for 220–250 V DC or 208–277 V AC, and two HQ auxiliary switches.

Where can I buy 3VA1116-6ED36-0KC0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.