Siemens 3VA1116-6ED46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1116-6ED46-0AA0 SENTRON MCCB, 160A, 4-Pole, 220kA

MPN3VA1116-6ED46-0AA0
Active

Siemens SENTRON 3VA1116-6ED46-0AA0, molded case circuit breaker, 4-pole, 160 A at 40 °C, TM210 thermal-magnetic release, breaking capacity 220 kA at 240 V, IP40 front, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1116-6ED46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA1116-6ED46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.38 W

Protection & Trip Unit

3VA1116-6ED46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1116-6ED46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1116-6ED46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1116-6ED46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1116-6ED46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

What this MCCB delivers

The Siemens 3VA1116-6ED46-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated 160 A at 40 °C, with 4 poles and a TM210 thermal-magnetic overcurrent release. It is designed for line protection — meaning it sits at the incoming feeder or main distribution point, not downstream branch circuits. The breaking capacity is 220 kA at 240 V, 154 kA at 415 V, and 75.6 kA at 440 V, so it handles high-fault utility feeds without cascading upstream. The TM210 release gives a fixed thermal curve and magnetic trip, no electronic adjustment. Front protection is IP40 — suitable for dry indoor panels; not rated for washdown.

Dimensions and panel fit

Width is 101.6 mm (4 in), depth 70 mm (2.76 in), height 130 mm (5.12 in). That 101.6 mm width is a standard 4-pole MCCB footprint — it occupies roughly four 1-inch pole spaces on a DIN rail or mounting plate. The 70 mm depth leaves clearance for rear busbars or cable ducts in a 200 mm deep enclosure. Verify the gland plate cutout matches the 101.6 mm width before drilling.

Current derating and thermal limits

Rated 160 A continuously at 40 °C, and it holds 160 A up to 50 °C. Above that, derating is gradual: 158 A at 55 °C, 155 A at 60 °C, 153 A at 65 °C, and 150 A at 70 °C. The maximum operating temperature is 70 °C; storage range is -40 °C to 80 °C. Power loss at full load is 38 W maximum — negligible for panel thermal budgeting but worth noting if the breaker is enclosed in a small sub-panel with other heat sources.

Frequently asked questions

Where can I buy 3VA1116-6ED46-0AA0 and how do I get a price?

We source this part to order against an RFQ. Submit a quote request through the storefront; availability and current pricing are confirmed at quote time.

What is 3VA1116-6ED46-0AA0's listed depth?

The depth is 70 mm (2.76 in).

What is 3VA1116-6ED46-0AA0's listed width?

The width is 101.6 mm (4 in).

Will 3VA1116-6ED46-0AA0 drop into a panel that was specified around 3VA1112-5EE32-0AA0 without rewiring?

Mechanically yes — both are 4-pole SENTRON 3VA breakers with the same 101.6 mm width and 70 mm depth, so the mounting holes and busbar positions align. However, the 3VA1116-6ED46-0AA0 is rated 160 A with a TM210 release, while the 3VA1112-5EE32-0AA0 is a different current rating and trip curve. Verify the load and protection coordination before swapping; the wiring lugs accept the same conductor sizes.

MPN
3VA1116-6ED46-0AA0