Siemens 3VA1120-3ED26-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1120-3ED26-0AA0 SENTRON MCCB, 2-pole, 20 A, TM210

MPN3VA1120-3ED26-0AA0
Active

Siemens SENTRON 3VA1120-3ED26-0AA0, molded case circuit breaker, 2-pole, 20 A (40 °C), TM210 thermal-magnetic release, 75.6 kA at 240 V AC, IP40 front, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1120-3ED26-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1120-3ED26-0AA0 — Ratings
ParameterValue
Number of poles2
Rated operational voltage Ue (AC)415 V
Rated insulation voltage Ui500 V
Current at 40 °C20 A
Current at 45 °C20 A
Current at 50 °C20 A
Current at 55 °C20 A
Current at 60 °C19 A
Current at 65 °C19 A
Current at 70 °C19 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Power loss, max.8 W
3VA1120-3ED26-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1120-3ED26-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1120-3ED26-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1120-3ED26-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1120-3ED26-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width50.8 mm
Depth70 mm
Height (in)5.12 in
Width (in)2 in
Depth (in)2.76 in

Product details

SENTRON 3VA1120-3ED26-0AA0 — 2-pole MCCB, 20 A, TM210 release

The TM210 overcurrent release combines a thermal bimetal for overload protection and a magnetic coil for short-circuit response. Interrupting capacity reaches 75.6 kA at 240 V AC and 52.5 kA at 415 V AC — figures that cover most industrial service-entrance and distribution panel fault levels without cascading upstream.

The IP40 front protection suits enclosed panel mounting.

Frequently asked questions

Will 3VA1120-3ED26-0AA0 drop into a panel specified around 3VA1110-5ED32-0AA0 without rewiring?

Both are 2-pole SENTRON 3VA frame MCCBs sharing the same 70 mm depth, 50.8 mm width, and 130 mm height — mechanical fit is identical. The difference is the release and rating: this one uses a TM210 thermal-magnetic release rated 20 A, while the 3VA1110-5ED32-0AA0 carries a different trip curve and amperage. Check the load-side conductor sizing and coordination study before swapping.

MPN
3VA1120-3ED26-0AA0