Skip to main content
Siemens 3VA1120-3ED32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1120-3ED32-0AA0 SENTRON MCCB, 20A, 75.6kA at 240V

MPN3VA1120-3ED32-0AA0
Active

Siemens SENTRON 3VA1120-3ED32-0AA0, 3-pole molded case circuit breaker, 20 A at 40 °C, TM210 thermal-magnetic trip, 75.6 kA interrupting at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1120-3ED32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1120-3ED32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C20 A
Current at 45 °C20 A
Current at 50 °C20 A
Current at 55 °C20 A
Current at 60 °C19 A
Current at 65 °C19 A
Current at 70 °C19 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.12 W
3VA1120-3ED32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1120-3ED32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1120-3ED32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1120-3ED32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1120-3ED32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

It's built for line protection — the workhorse of a distribution panel or motor branch circuit where you need adjustable overload and fixed instantaneous short-circuit response. At 240 V AC it can interrupt 75.6 kA, which gives solid SCCR headroom for most industrial service entrances or sub-feeders. The interrupting rating drops to 52.5 kA at 415 V and 32 kA at 440 V, so check your available fault current before specifying — that 75.6 kA number only holds at the lower voltage.

Sizing and thermal performance

At 60 °C and 65 °C it still carries 19 A, and at 70 °C it stays at 19 A. That's a wide thermal plateau; you won't lose capacity unless your enclosure runs hotter than 55 °C regularly. Maximum power loss is 12 W. For a 20 A MCCB that's reasonable — it won't cook adjacent devices in a crowded panel, but don't stack it tight against heat-sensitive electronics without a little air gap.

Footprint is 76.2 mm wide, 130 mm tall, 70 mm deep — standard for a SENTRON 3VA frame. It's a plain line-protection MCCB — if you need shunt trip or remote status, you're looking at a different order code in the 3VA family.

Frequently asked questions

What is the trip unit type on this MCCB?

It uses a TM210 thermal-magnetic overcurrent release — fixed thermal and magnetic settings for line protection.

MPN