Skip to main content
Siemens 3VA1120-3EF32-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1120-3EF32-0AA0-ZD00 Circuit Breaker, 20A, 25kA @

MPN3VA1120-3EF32-0AA0-ZD00

Siemens 3VA1 IEC frame 160, 3-pole circuit breaker, breaking capacity class N, Icu=25kA @ 415V, line protection TM240, ATAM, In=20A, overload protection Ir=14A...20A, short-circuit protection Ii=8...16 x In, nut keeper kit for DC Power OEM in China.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1120-3EF32-0AA0-ZD00 is a 3VA1 IEC frame 160, 3-pole molded case circuit breaker (MCCB) with a 20 A rated current (In) and a 25 kA ultimate breaking capacity (Icu) at 415 V AC, classification N. The thermal-magnetic trip unit (TM240) provides adjustable overload protection (Ir) from 14 A to 20 A, letting you fine-tune the continuous current threshold to match the downstream cable or load without swapping the breaker body. The short-circuit magnetic pickup (Ii) is fixed at 8 to 16 times In (160 A to 320 A), which is typical for motor and distribution feeder protection — high enough to avoid nuisance trips on inrush, low enough to clear a bolted fault fast. This variant includes a nut keeper kit and is designated for a DC Power OEM in China, so the hardware package is pre-configured for that assembly line. The breaker itself is standard 3VA1 platform — same frame, same breaking capacity, same trip curve — the ZD00 suffix flags the OEM-specific accessory kit.

Deployment context — where this breaker fits

The 3-pole configuration suits three-phase circuits — feeder protection for a 20 A motor branch, a lighting panel, or a small distribution sub-panel in a 415 V industrial installation. If your system's prospective short-circuit current is higher, you need a higher-rated upstream device or a current-limiting breaker.

Frequently asked questions

Where can I buy the 3VA1120-3EF32-0AA0-ZD00 and get a price?

This part is sourced to order against an RFQ through independent and authorized distribution. Submit a request for quote (RFQ) to confirm availability and current pricing at the time of your order.

What is the breaking capacity of this breaker?

The ultimate breaking capacity (Icu) is 25 kA at 415 V AC, which is the maximum fault current the breaker can safely interrupt once without damage.

What does the TM240 trip unit mean?

TM240 is a thermal-magnetic trip unit with adjustable overload protection (Ir) from 14 A to 20 A and a fixed short-circuit pickup (Ii) of 8 to 16 times In (160 A to 320 A), providing both long-time and instantaneous protection for cable and load.

MPN
3VA1120-3EF32-0AA0-ZD00