Skip to main content
Siemens 3VA1120-3EF32-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1120-3EF32-0AF0 SENTRON MCCB, 20 A, 3-Pole, TM240

MPN3VA1120-3EF32-0AF0

Siemens SENTRON 3VA1120-3EF32-0AF0, 3-pole molded case circuit breaker, 20 A rated continuous current, TM240 thermal-magnetic release, 75.6 kA breaking capacity at 240 V, IP40 front protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1120-3EF32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1120-3EF32-0AF0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C20 A
Current at 45 °C20 A
Current at 50 °C20 A
Current at 55 °C19.2 A
Current at 60 °C18.8 A
Current at 65 °C18.4 A
Current at 70 °C18 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V10.5 kA
3VA1120-3EF32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1120-3EF32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1120-3EF32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1120-3EF32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1120-3EF32-0AF0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The 75.6 kA interrupting rating at 240 V drops to 52.5 kA at 415 V and 32 kA at 440 V, so the SCCR headroom shrinks fast as line voltage climbs — verify your available fault current against the 415 V or 440 V column if you're on a 400 V-class system.

Rated continuous current holds flat at 20 A from 40 °C to 50 °C, then derates to 19.2 A at 55 °C and 18 A at 70 °C — usable in warm enclosures but the headroom narrows above 50 °C. The 3-pole block is 76.2 mm wide, 130 mm tall, 70 mm deep, and carries 1 auxiliary switch plus 1 trip alarm contact (HQ version) built in, so you don't need a separate aux block for status feedback.

Frequently asked questions

What is the breaking capacity of 3VA1120-3EF32-0AF0 at different voltages?

75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 10.5 kA at 690 V — the interrupting rating drops significantly as voltage increases.

Where can I buy 3VA1120-3EF32-0AF0?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN
3VA1120-3EF32-0AF0