Skip to main content
Siemens 3VA1120-3EF32-0JH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1120-3EF32-0JH0 SENTRON MCCB, 20 A, 3-Pole, 75.6

MPN3VA1120-3EF32-0JH0

Siemens SENTRON 3VA1120-3EF32-0JH0, 3-pole molded case circuit breaker for line protection, 20 A rated current, 75.6 kA interrupting capacity at 240 V, with shunt trip and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1120-3EF32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11203EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1120-3EF32-0JH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C20 A
Current at 45 °C20 A
Current at 50 °C20 A
Current at 55 °C20 A
Current at 60 °C19 A
Current at 65 °C19 A
Current at 70 °C19 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.12 W

Protection & Trip Unit

3VA1120-3EF32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1120-3EF32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1120-3EF32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1120-3EF32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1120-3EF32-0JH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What this MCCB carries

The Siemens SENTRON 3VA1120-3EF32-0JH0 is a 3-pole molded case circuit breaker designed for line protection in distribution panels. It carries a 20 A continuous rating across the 40 °C to 55 °C band, derating to 19 A at 60 °C and above — a thermal curve that suits lightly loaded feeders in ventilated enclosures. Its interrupting capacity reaches 75.6 kA at 240 V, 52.5 kA at 415 V, and 32 kA at 440 V, with 11.9 kA holding at both 500 V and 690 V. That SCCR range covers most industrial service-entrance and sub-feed applications; the 690 V rating is useful for 600 V class Canadian or mining panels.

Integrated accessories for control wiring

Factory-fitted with a shunt trip (STL) and a complement of 2 auxiliary switches plus 1 trip alarm switch (HQ configuration). This avoids separate accessory mounting and wiring in the panel — the shunt trip allows remote tripping from an E-stop or PLC output, while the alarm switch signals a fault condition back to the control system. No undervoltage release is fitted, so the breaker holds in without a separate coil-monitoring circuit. The 12 W maximum power loss is the total dissipation at rated load; factor it into enclosure thermal calculations if the panel is tightly packed.

Compliance and documentation

The SENTRON 3VA series carries IEC/EN 60947-2 certification for molded case circuit breakers. Rated insulation voltage is 800 V, which covers 690 V systems with margin. The manufacturer provides CE, UKCA, and EAC declarations, plus RoHS and REACH compliance statements with the product documentation package. No integrated communication function — this is a standalone thermal-magnetic breaker, not a power-metering or networked device.

Frequently asked questions

Where can I buy the 3VA1120-3EF32-0JH0 and what is the lead time?

This MCCB is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm delivery commitment.

What is the interrupting capacity of the 3VA1120-3EF32-0JH0 at different voltages?

75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at both 500 V and 690 V.

Will the 3VA1120-3EF32-0JH0 drop into a panel specified for the 3VA1110-5EF32-0AM0?

Yes — the 70 mm depth, 76.2 mm width, and 130 mm height are identical, so the mechanical footprint and mounting hole pattern match. The wiring difference is in the accessory circuit: this unit carries a shunt trip and 2 auxiliary + 1 alarm switch, which the 3VA1110 may not. Verify the control wiring scheme before swapping.

MPN
3VA1120-3EF32-0JH0