Siemens 3VA1120-4EF36-0CH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1120-4EF36-0CH0 SENTRON MCCB, 20 A, 3-Pole, 121 k

MPN3VA1120-4EF36-0CH0

Siemens SENTRON 3VA1120-4EF36-0CH0, molded case circuit breaker, 3-pole, 20 A rated at 40 °C, 121 kA breaking at 240 V, line protection design, undervoltage release, 70 mm depth.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1120-4EF36-0CH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11204EF360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1120-4EF36-0CH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C20 A
Current at 45 °C20 A
Current at 50 °C20 A
Current at 55 °C20 A
Current at 60 °C19 A
Current at 65 °C19 A
Current at 70 °C19 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.14.5 W

Protection & Trip Unit

3VA1120-4EF36-0CH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1120-4EF36-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1120-4EF36-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1120-4EF36-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1120-4EF36-0CH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

MCCB for panel builders

The Siemens SENTRON 3VA1120-4EF36-0CH0 is a 3-pole molded case circuit breaker rated 20 A at 40 °C ambient, with a breaking capacity of 121 kA at 240 V AC — enough to handle high-fault utility feeds in industrial distribution panels. The line-protection design means it trips on overload and short-circuit, not on ground fault; the undervoltage release (UVR) lets a safety PLC or E-stop chain drop the breaker when control voltage disappears. Panel builders mounting on DIN rail or direct plate will find the 70 mm depth and 76.2 mm width fit standard MCCB footprints.

Breaking capacity and thermal derating

Rated uninterrupted current holds at 20 A from 40 °C through 55 °C, then derates to 19 A at 60 °C and 19 A at 70 °C — no derating loss in typical 40 °C panel ambient. The interrupting ratings cover the common distribution voltages: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 500 V and 690 V. Insulation voltage is rated 800 V, so the breaker can be applied in 690 V line-to-line systems with adequate clearance.

Auxiliary and release configuration

Factory-fitted with 2 auxiliary switches plus 1 trip alarm switch (HQ configuration) — enough to signal breaker position and fault status back to a PLC or SCADA. The undervoltage release (UVR) is built in; no external undervoltage module needed. Maximum power loss is 14.5 W, relevant for thermal budgeting inside a sealed enclosure.

Environmental limits

Operating ambient range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. The storage minimum is below typical warehouse conditions, so no cold-weather handling restrictions.

Frequently asked questions

How do I get pricing and availability for 3VA1120-4EF36-0CH0?

Submit an RFQ. This part is sourced to order through independent distribution; current pricing and stock levels are confirmed at quote time.

What is the breaking capacity of this MCCB at 240 V?

121 kA at 240 V AC — suitable for high-fault-capacity service entrance or distribution panels.

Does this breaker include an undervoltage release?

Yes, it is factory-fitted with an undervoltage release (UVR) for remote trip via control voltage loss.

What auxiliary switches come with 3VA1120-4EF36-0CH0?

Two auxiliary switches plus one trip alarm switch (HQ design) are included for status feedback.

MPN