Siemens 3VA1120-5ED32-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA1120-5ED32-0AA0-ZD00 MCCB, 55kA @ 415V, 2

MPN3VA1120-5ED32-0AA0-ZD00

Siemens SENTRON 3VA1 series, molded case circuit breaker, IEC frame 160, breaking capacity class M, 55 kA @ 415 V AC, 3-pole, line protection TM210, In = 20 A fixed, nut keeper kit for DC Power OEM in China.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1120-5ED32-0AA0-ZD00 — Identification
ParameterValue
Brand / rangeSENTRON

Product details

What this MCCB delivers for your panel

The Siemens SENTRON 3VA1120-5ED32-0AA0-ZD00 is a 3-pole molded case circuit breaker on the IEC frame 160 platform, rated for 55 kA breaking capacity at 415 V AC — that is the class M interrupting rating, meaning it clears bolted faults up to that level without upstream fuses or a larger frame taking over. The thermal-magnetic release is a TM210, set fixed at 20 A (Ir = In) with a short-circuit pickup of 16× In, so it protects a 20 A feeder or load circuit against sustained overloads and instantaneous faults. The nut keeper kit variant (ZD00 suffix) is configured for DC Power OEM applications in China, with box terminals on both sides and front connection.

What the ratings mean for fit

The 55 kA @ 415 V breaking capacity (class M) is the key coordination number: it tells you this breaker can be applied downstream of a transformer or upstream feeder with a prospective fault current up to that level, and it will interrupt without welding contacts or venting arc gas into the enclosure. The TM210 release with Ii = 16 × In (320 A instantaneous pickup) is a line-protection curve — it is not a motor-protection or generator curve, so it is sized for cable and busbar protection, not for starting inrush. The 20 A fixed rating means no adjustment band; you order the exact amp rating the branch circuit needs.

Panel integration notes

The 3VA1 frame is a standard panel-mount MCCB — 76.2 mm wide, 130 mm tall, 70 mm deep — with front terminals and box lugs on both sides. It accepts stranded conductors up to 70 mm² per pole. The IP40 front protection is typical for enclosed distribution boards; no additional sealing is needed inside a rated panel. The nut keeper kit (ZD00) is a mechanical detail for the DC Power OEM variant — it retains the terminal nuts during assembly in high-vibration or high-throughput production.

Frequently asked questions

Where can I buy 3VA1120-5ED32-0AA0-ZD00 and get a price?

We source this part to order against an RFQ. Submit a request and we will confirm availability and current pricing at quote time.

What is the breaking capacity of this MCCB?

It is rated 55 kA at 415 V AC, class M on the IEC frame 160 platform — sufficient for most industrial distribution panels with a transformer secondary fault current in that range.

Does 3VA1120-5ED32-0AA0-ZD00 drop into a panel specified for 3VA1110-5MH36-0AA0?

Both are 3-pole 3VA1 frame breakers with the same 76.2 mm width, 130 mm height, and 70 mm depth, so the physical footprint and terminal arrangement are identical. The difference is the release: this one is a TM210 line-protection breaker at 20 A fixed, while the 3VA1110-5MH36-0AA0 is a starter-protection version with a TM120M release. They are not electrically interchangeable for the same protection function — verify the trip curve and amp rating against your load before substituting.