Skip to main content
Siemens 3VA1120-5EE36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1120-5EE36-0AA0 SENTRON MCCB, 20A 3-Pole, 187kA@2

MPN3VA1120-5EE36-0AA0
Active

Siemens SENTRON 3VA1120-5EE36-0AA0, 3-pole molded case circuit breaker, 20 A rated, TM220 thermal-magnetic trip, 187 kA interrupting capacity at 240 V AC, line protection design.

$116.84Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1120-5EE36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1120-5EE36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C20 A
Current at 45 °C20 A
Current at 50 °C20 A
Current at 55 °C20 A
Current at 60 °C19 A
Current at 65 °C19 A
Current at 70 °C19 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.12 W
3VA1120-5EE36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1120-5EE36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1120-5EE36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1120-5EE36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1120-5EE36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Siemens 3VA1120-5EE36-0AA0 — 20 A MCCB, 187 kA SCCR, Active Line

Rated 20 A continuously at 40 °C (derates to 19 A above 60 °C), this breaker carries a 187 kA interrupting capacity at 240 V AC — enough to clear high-fault utility feeds without cascading upstream.

Sourcing & Lifecycle — Active, Quoted to Order

The 3VA1120-5EE36-0AA0 is a current-catalog item with no announced last-time-buy. Compliance documentation (RoHS, REACH, IEC/UL ratings) is available from the manufacturer's support portal.

Peer Comparison — 3VA1110-5ED36-0AA0

The closest functional sibling is the 3VA1110-5ED36-0AA0, which shares the same 3-pole, TM220 trip, and 20 A frame but uses a lower interrupting rating (typically 100–150 kA at 240 V vs. 187 kA on this unit).

Frequently asked questions

Will 3VA1120-5EE36-0AA0 drop into a panel built for 3VA1110-5ED36-0AA0?

Yes — same 3-pole frame, same 76.2 mm width and 70 mm depth, same TM220 trip. The only difference is the higher interrupting rating on the 3VA1120-5EE36-0AA0, so it fits the same cutout and wiring without modification.

MPN
3VA1120-5EE36-0AA0