Skip to main content
Siemens 3VA1120-5EF36-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1120-5EF36-0HC0 SENTRON MCCB, 20 A, 187 kA at 240

MPN3VA1120-5EF36-0HC0

Siemens SENTRON 3VA1120-5EF36-0HC0, 3-pole molded case circuit breaker, 20 A rated current, TM240 thermal-magnetic release, 187 kA at 240 V, shunt trip, 2 HQ auxiliary switches, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1120-5EF36-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1120-5EF36-0HC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C20 A
Current at 45 °C20 A
Current at 50 °C20 A
Current at 55 °C19.2 A
Current at 60 °C18.8 A
Current at 65 °C18.4 A
Current at 70 °C18 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA
3VA1120-5EF36-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1120-5EF36-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1120-5EF36-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1120-5EF36-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1120-5EF36-0HC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Siemens 3VA1120-5EF36-0HC0 — SENTRON 3-pole MCCB, 20 A, line protection

Breaking capacity reaches 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V — figures that define the maximum fault current the device can safely interrupt at each voltage level, which is the primary selection criterion for SCCR compliance in a distribution panel.

At 55 °C it derates to 19.2 A, at 60 °C to 18.8 A, at 65 °C to 18.4 A, and at 70 °C to 18 A.

Integrated auxiliary and release configuration

The integrated auxiliary trip is order code 3VA9688-0BL30. There is no undervoltage release, no ground fault monitoring, no phase failure detection, and no communication function — the part is a straightforward line-protection device without remote monitoring or GFCI capability. The front face carries IP40 protection; the enclosure is sized at 130 mm height, 76.2 mm width, and 70 mm depth, which governs the DIN-rail or mounting-plate footprint.

Frequently asked questions

Where can I buy 3VA1120-5EF36-0HC0 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is 3VA1120-5EF36-0HC0's breaking capacity at 240 V?

The breaking capacity is 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V.

What auxiliary releases are fitted on this MCCB?

It includes a shunt trip (STL) auxiliary release and 2 HQ-type auxiliary switches. The integrated auxiliary trip order code is 3VA9688-0BL30. No undervoltage release is fitted.

MPN
3VA1120-5EF36-0HC0