Siemens 3VA1120-6MH32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1120-6MH32-0AA0 SENTRON MCCB, 20 A, 220 kA at 240

MPN3VA1120-6MH32-0AA0
Active

Siemens SENTRON 3VA1120-6MH32-0AA0, molded case circuit breaker, 3-pole, 20 A, 220 kA at 240 V, starter protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1120-6MH32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1120-6MH32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C20 A
Current at 45 °C20 A
Current at 50 °C20 A
Current at 55 °C20 A
Current at 60 °C19 A
Current at 65 °C19 A
Current at 70 °C19 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.12 W
3VA1120-6MH32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM120M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1120-6MH32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1120-6MH32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1120-6MH32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1120-6MH32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Its TM120M thermal-magnetic overcurrent release provides inverse-time overload protection plus instantaneous short-circuit trip, sized for a 20 A continuous load at 40 °C through 55 °C; at 60 °C it derates to 19 A, holding to 19 A through 70 °C. The headline breaking capacity is 220 kA at 240 VAC, dropping to 154 kA at 415 VAC, 121 kA at 440 VAC, and 7.5 kA at both 500 VAC and 690 VAC — so at higher line voltages the interrupting capability falls sharply, and the 7.5 kA figure at 500/690 V is the one that governs coordination in a 480/600 V panel.

Where it is used and how it mounts

This MCCB is intended for panel or enclosure mounting in motor control centers, starter assemblies, and industrial control panels where the breaker protects a motor starter branch. It occupies a 76.2 mm wide by 130 mm tall by 70 mm deep footprint (3 in × 5.12 in × 2.76 in). The design is for fixed mounting — not a plug-in base — so panel cutouts and bus connections must be planned for this specific frame size.

Frequently asked questions

What is the breaking capacity of 3VA1120-6MH32-0AA0 at 240 V?

220 kA at 240 VAC. At 415 VAC it is 154 kA, at 440 VAC it is 121 kA, and at 500 VAC and 690 VAC it is 7.5 kA.

What is the rated current of 3VA1120-6MH32-0AA0 at 40 °C?

20 A at 40 °C through 55 °C, derating to 19 A at 60 °C through 70 °C.

Where can I buy 3VA1120-6MH32-0AA0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures or lead-time numbers are published here.

What is the overcurrent release type on this MCCB?

TM120M — a thermal-magnetic release providing inverse-time overload and instantaneous short-circuit protection, tuned for starter protection duty.

MPN
3VA1120-6MH32-0AA0