Skip to main content
Siemens 3VA1125-3EF32-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1125-3EF32-0BH0 SENTRON MCCB, 25 A, 3-Pole, 75.6

MPN3VA1125-3EF32-0BH0

Siemens SENTRON 3VA1125-3EF32-0BH0, molded case circuit breaker, 3-pole, 25 A, 75.6 kA interrupting at 240 V, line protection, undervoltage release, 70 x 76.2 x 130 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1125-3EF32-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11253EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1125-3EF32-0BH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C24 A
Current at 60 °C24 A
Current at 65 °C23 A
Current at 70 °C23 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.11 W
3VA1125-3EF32-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1125-3EF32-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1125-3EF32-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1125-3EF32-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1125-3EF32-0BH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What this MCCB actually carries

Siemens SENTRON 3VA1125-3EF32-0BH0 is a 3-pole molded case circuit breaker rated 25 A continuous at 40 °C — and holds that full 25 A right up to 50 °C before it starts to derate (24 A at 55 °C, 23 A at 70 °C). That thermal curve means you don't lose headroom in a warm panel unless it's pushing 55 °C inside. Interrupting capacity varies by system voltage: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at 500 V or 690 V. That's enough for most secondary distribution panels downstream of a transformer — the 415 V figure covers common IEC industrial feeds. Max power loss runs 11 W — manageable for thermal budgeting in a crowded enclosure.

What's built in — and what's not

If your control scheme needs the breaker to drop out on loss of control voltage, you're covered. This is a straight line-protection MCCB with mechanical auxiliaries — for a managed or communicating breaker you'd step to a different suffix.

Active — no lifecycle concern

Trip indicator is present — visual confirmation of trip state without needing to open the cover.

MPN
3VA1125-3EF32-0BH0