Siemens 3VA1125-3EF32-0CA0 SENTRON MCCB, 25A, 75.6kA at 240V

MPN3VA1125-3EF32-0CA0

Siemens SENTRON 3VA1125-3EF32-0CA0, 3-pole molded case circuit breaker, 25 A at 40 °C, 75.6 kA interrupting at 240 V, TM240 overcurrent release, undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1125-3EF32-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11253EF320AA0
3VA1125-3EF32-0CA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C24 A
Current at 60 °C24 A
Current at 65 °C23 A
Current at 70 °C23 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.11 W
3VA1125-3EF32-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1125-3EF32-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1125-3EF32-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1125-3EF32-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1125-3EF32-0CA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

It's the kind of breaker you spec into a distribution panel when you need a clean interrupting curve and a UVR to drop the load on voltage loss — no comms, no ground-fault monitoring, just a solid overcurrent trip and undervoltage supervision.

Rated 25 A continuous at 40 °C, and it holds that rating through 50 °C — only starts to derate at 55 °C (24 A) and 65 °C (23 A). That's a solid thermal curve for a panel running warm; you don't lose headroom until the ambient pushes past 50 °C. Interrupting capacity is 75.6 kA at 240 V, dropping to 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at 500/690 V. The TM240 release handles the thermal-magnetic trip curve; no electronic adjustment, no communication module — straightforward overcurrent protection with a UVR for undervoltage dropout.

That's a compact 3-pole MCCB — fits standard panel-mount cutouts for the SENTRON 3VA frame.

Frequently asked questions

Does this breaker include an undervoltage release?

Yes, it has an integrated undervoltage release (UVR) for dropout on voltage loss.

What overcurrent release does this MCCB use?

A TM240 thermal-magnetic release — fixed thermal and magnetic trip settings, no electronic adjustment.

MPN
3VA1125-3EF32-0CA0