Skip to main content
Siemens 3VA1125-3EF32-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1125-3EF32-0CC0 SENTRON MCCB, 25A, 3-Pole, 75.6kA

MPN3VA1125-3EF32-0CC0

Siemens SENTRON 3VA1125-3EF32-0CC0, molded case circuit breaker, 3-pole, 25 A at 40 °C, line protection, with undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1125-3EF32-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11253EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1125-3EF32-0CC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C24 A
Current at 60 °C24 A
Current at 65 °C23 A
Current at 70 °C23 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.11 W
3VA1125-3EF32-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1125-3EF32-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1125-3EF32-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1125-3EF32-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1125-3EF32-0CC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1125-3EF32-0CC0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying 25 A continuously at 40 °C and derating to 23 A at 70 °C. Its interrupting capacity hits 75.6 kA at 240 V and still holds 11.9 kA at 690 V — enough headroom for most industrial distribution panels without cascading upstream.

At 415 V it interrupts 52.5 kA, at 440 V it's 32 kA, and at 500 V it drops to 11.9 kA — the same figure holds at 690 V. That curve tells you where this breaker sits in a selective coordination study: it clears high-fault scenarios at the lower voltages common in North American 480Y/277 V panels, but at 690 V you're coordination-limited to about 12 kA available fault current.

Built-in undervoltage release

The auxiliary switch configuration is 2 auxiliary switches HQ, so you get status feedback without adding a separate accessory module.

The 3VA1125-3EF32-0CC0 measures 130 mm high, 76.2 mm wide, and 70 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures without re-drilling.

Frequently asked questions

What is the interrupting capacity of this breaker at 240 V?

At 240 V the interrupting capacity is 75.6 kA. At 415 V it's 52.5 kA, at 440 V it's 32 kA, and at 500 V and 690 V it's 11.9 kA.

Does this MCCB include an undervoltage release?

Yes, this variant is fitted with an undervoltage release (UVR) as the auxiliary release, plus 2 auxiliary switches HQ for status feedback.

Where can I buy the 3VA1125-3EF32-0CC0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or price figures are published here.

MPN