Siemens 3VA1125-3GF42-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1125-3GF42-0AA0-ZD00 Circuit Breaker, 25A, 25kA @

MPN3VA1125-3GF42-0AA0-ZD00

Siemens 3VA1 IEC frame 160, breaking capacity class N, Icu=25kA @ 415V, 4-pole, line protection TM240, ATAM, In=25A, overload protection Ir=18A...25A, short-circuit protection Ii=6.4...12.8 x In, N conductor protection 100%, nut keeper kit for DC Power OEM in China.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

What this breaker is and what it does

The Siemens 3VA1125-3GF42-0AA0-ZD00 is a 4-pole IEC frame 160 molded-case circuit breaker with a 25 A continuous rating (In=25A) and a breaking capacity class N — Icu=25 kA at 415 V. That 25 kA interrupting rating means it can safely clear a fault up to that level on a 415 V three-phase system without welding contacts or rupturing the case, which is the standard for downstream distribution panels and motor branch circuits in IEC markets.

Adjustable protection and what it means on the line

Overload protection (Ir) is adjustable from 18 A to 25 A via the TM240 thermal-magnetic trip unit — you dial it to match the actual load current, not the breaker frame. Short-circuit magnetic pickup (Ii) is set at 6.4 to 12.8 times In, which for a 25 A breaker means the instantaneous trip point ranges from 160 A to 320 A. That range lets you coordinate with downstream devices: set low for sensitive loads (e.g., control transformers), set high to ride through motor inrush on a conveyor or pump start.

Where it fits in the panel

This breaker mounts on a standard DIN rail in the enclosure. The 100% N-conductor protection means the neutral pole is fully rated and protected — no derating needed for single-phase line-to-neutral faults. The nut keeper kit is included for DC Power OEM applications in China, so if you're building a DC bus distribution panel, the hardware for secure bus-bar connections is already in the box.

Frequently asked questions

What is the breaking capacity of this breaker?

Icu=25 kA at 415 V, breaking capacity class N per IEC 60947-2. That means it can safely interrupt a fault current up to 25,000 A at 415 V without damage.

What is the adjustable overload range on this breaker?

Overload protection Ir is adjustable from 18 A to 25 A via the TM240 thermal-magnetic trip unit. Short-circuit magnetic pickup Ii is adjustable from 6.4 to 12.8 times In (160 A to 320 A for the 25 A frame).

Where can I buy 3VA1125-3GF42-0AA0-ZD00 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3VA1125-3GF42-0AA0-ZD00