Skip to main content
Siemens 3VA1125-4EF32-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1125-4EF32-0AC0 SENTRON MCCB, 25 A, 3-Pole, 121 k

MPN3VA1125-4EF32-0AC0

Siemens SENTRON 3VA1125-4EF32-0AC0, molded case circuit breaker, 3-pole, 25 A, line protection, TM240 thermal-magnetic release, 121 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1125-4EF32-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1125-4EF32-0AC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C24 A
Current at 60 °C23.5 A
Current at 65 °C23 A
Current at 70 °C22.5 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA
3VA1125-4EF32-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1125-4EF32-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1125-4EF32-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1125-4EF32-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1125-4EF32-0AC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The 25 A rating holds flat from 40 °C up to 50 °C; above that it derates to 24 A at 55 °C, 23.5 A at 60 °C, 23 A at 65 °C, and 22.5 A at 70 °C, so for a panel that runs warm the continuous load needs to stay under the derated curve, not the nameplate value. The interrupting ratings are the headline: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 690 V. It carries two built-in auxiliary switches (HQ type) for remote status indication — no separate auxiliary module needed for basic open/closed signalling.

The breaker measures 76.2 mm wide, 130 mm tall, and 70 mm deep — a standard 3-pole MCCB footprint that fits a 3-pole SENTRON mounting base or direct panel-mount. No special cutout or adapter plate required for a typical distribution panel. The TM240 release is factory-set; no field adjustment of the thermal curve, so the trip coordination is fixed once the breaker is sized to the downstream load.

MPN
3VA1125-4EF32-0AC0