Skip to main content
Siemens 3VA1125-5EF32-0HH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1125-5EF32-0HH0 SENTRON MCCB, 25 A, 3-Pole, 187 k

MPN3VA1125-5EF32-0HH0

Siemens SENTRON 3VA1125-5EF32-0HH0, molded case circuit breaker, 3-pole, 25 A, line protection, 187 kA at 240 V, 70 mm depth, 76.2 mm width, 130 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1125-5EF32-0HH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11255EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1125-5EF32-0HH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C24 A
Current at 60 °C24 A
Current at 65 °C23 A
Current at 70 °C23 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.8.5 W
3VA1125-5EF32-0HH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1125-5EF32-0HH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1125-5EF32-0HH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1125-5EF32-0HH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1125-5EF32-0HH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Siemens 3VA1125-5EF32-0HH0 — 25 A SENTRON MCCB with 187 kA Interrupting Capacity

At 415 V it interrupts 121 kA, at 440 V it handles 75.6 kA, and at 500 V and 690 V it is rated for 17 kA each.

Above that it derates: 24 A at 55 °C and 60 °C, 23 A at 65 °C and 70 °C. The 8.5 W maximum power loss matters for enclosure thermal budgeting — in a sealed panel with multiple breakers, that heat adds up. Dimensions are 70 mm deep, 76.2 mm wide, and 130 mm tall, fitting standard SENTRON 3VA panel footprints.

Frequently asked questions

Who supplies 3VA1125-5EF32-0HH0 and how is it quoted for volume purchases?

This part is sourced through independent industrial distribution channels and quoted to order against an RFQ. Volume pricing and lead time are confirmed at quote time — submit an RFQ for current availability and pricing.

What is the interrupting capacity of 3VA1125-5EF32-0HH0 at 240 V?

The maximum interrupting capacity at 240 V is 187 kA. At 415 V it is 121 kA, at 440 V it is 75.6 kA, and at 500 V and 690 V it is 17 kA.

MPN
3VA1125-5EF32-0HH0