Siemens 3VA1125-6ED46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1125-6ED46-0AA0 SENTRON MCCB, 25 A, 4-Pole, 220 k

MPN3VA1125-6ED46-0AA0
Active

Siemens SENTRON 3VA1125-6ED46-0AA0, 4-pole molded case circuit breaker, 25 A rated current, TM210 thermal-magnetic release, 220 kA breaking capacity at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1125-6ED46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA1125-6ED46-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C24 A
Current at 60 °C24 A
Current at 65 °C23 A
Current at 70 °C23 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.8.5 W

Protection & Trip Unit

3VA1125-6ED46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout

Construction & Connection

3VA1125-6ED46-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1125-6ED46-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1125-6ED46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1125-6ED46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

Siemens SENTRON 3VA1125-6ED46-0AA0 — 25 A, 4-Pole MCCB with TM210 Release

The Siemens 3VA1125-6ED46-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for 25 A continuous current (Iu) with a 4-pole configuration. It uses a TM210 thermal-magnetic overcurrent release, meaning the thermal element handles overloads and the magnetic element handles short-circuits — no electronic adjustment beyond the magnetic pickup. Breaking capacity is the headline here: 220 kA at 240 V AC, 154 kA at 415 V, 121 kA at 440 V, and still 17 kA at 500 V and 690 V. That 220 kA figure at 240 V is exceptionally high — this breaker is designed for high-fault-current installations, typically downstream of large transformers or in industrial mains where available fault current exceeds standard 65 kA or 100 kA ratings. The adjustable short-circuit release (Ii) can be set up to 320 A, giving flexibility to coordinate with downstream devices. The rated insulation voltage (Ui) is 800 V, and the maximum DC operational voltage is 600 V — so it can also serve in DC circuits like battery banks or DC bus distribution.

Thermal Derating and Panel Integration

Current rating is 25 A at 45 °C and 50 °C, derating to 24 A at 55 °C and 60 °C, then 23 A at 65 °C and 70 °C. That 2 A drop across the full temperature range is modest — the breaker holds its rating well in warm enclosures. Mounted on a DIN rail or panel, the 70 mm depth and 101.6 mm width fit standard MCCB footprints. IP40 on the front means protection against tools and wires >1 mm — standard for panel-mounted breakers. No internal communication function, no ground-fault monitoring built in; those are separate accessory modules. The motor drive option (Product Extension Optional) allows remote motorized operation for automated disconnection. Power loss is 8.5 W maximum at rated current — useful for thermal budget calculations in a sealed enclosure. Storage temperature range is -40 °C to 80 °C; operating range is -25 °C to 70 °C.

Selectivity and Coordination Notes

For selectivity studies: the 220 kA at 240 V and 154 kA at 415 V mean this breaker can be the main or feeder device in high-fault panels. The TM210 release is fixed thermal (25 A) with adjustable magnetic (Ii up to 320 A) — coordinate the magnetic pickup with downstream breakers to avoid nuisance tripping on motor inrush or capacitor charging currents. The 4-pole design covers three-phase plus neutral protection (or switched neutral). The N-conductor protection design is listed as 'Without', meaning the neutral pole is switched but not protected — typical for TN systems where neutral overcurrent is not expected.

Frequently asked questions

Where can I buy the 3VA1125-6ED46-0AA0 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — no stock count or price is published here.

What is the breaking capacity of the 3VA1125-6ED46-0AA0 at different voltages?

Breaking capacity is 220 kA at 240 V AC, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at both 500 V and 690 V AC.

Does the 3VA1125-6ED46-0AA0 have communication functions or ground-fault monitoring?

No. Communication function is not included, and ground-fault monitoring is not built in. These require separate accessory modules.

MPN
3VA1125-6ED46-0AA0