Siemens 3VA1125-6EF32-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1125-6EF32-0CC0 SENTRON MCCB, 25 A, 220 kA at 240

MPN3VA1125-6EF32-0CC0

Siemens SENTRON 3VA1125-6EF32-0CC0, 3-pole molded case circuit breaker, line protection, 25 A rated continuous current Iu, TM240 thermal-magnetic release, interrupting capacity 220 kA at 240 V, with undervoltage release and 2 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1125-6EF32-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1125-6EF32-0CC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C24 A
Current at 60 °C23.5 A
Current at 65 °C23 A
Current at 70 °C22.5 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 690 V17 kA
3VA1125-6EF32-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1125-6EF32-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1125-6EF32-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1125-6EF32-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1125-6EF32-0CC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Its interrupting capacity hits 220 kA at 240 V, 154 kA at 415 V, and 121 kA at 440 V — numbers that tell you this breaker is built for high-fault-current panels where upstream coordination demands serious SCCR headroom. At 690 V it still clears 17 kA, which is useful for industrial drives fed from a 690 V distribution bus.

The 25 A rating holds flat from 40 °C through 50 °C, then derates to 24 A at 55 °C, 23.5 A at 60 °C, 23 A at 65 °C, and 22.5 A at 70 °C. That's a shallow derate curve — you can run this breaker near its nameplate in a warm enclosure without losing much headroom.

Built-in undervoltage release

No separate UVR module to buy and mount.

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a standard 3-pole MCCB footprint that fits SENTRON distribution panels and most DIN-rail-mount enclosures.

Frequently asked questions

Where can I buy the 3VA1125-6EF32-0CC0 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here, but a quote request will return real-time supply posture.

What is the interrupting capacity of the 3VA1125-6EF32-0CC0 at different voltages?

At 240 V it clears 220 kA, at 415 V it clears 154 kA, at 440 V it clears 121 kA, and at 690 V it clears 17 kA. These ratings make it suitable for high-fault-current distribution panels.

Does the 3VA1125-6EF32-0CC0 include an undervoltage release?

Yes, this order code comes with an integrated undervoltage release (UVR) as standard — the design of the auxiliary release is undervoltage release (UVR), and the integrated auxiliary trip is listed as 3VA9608-0BB24.

MPN