Siemens 3VA1132-3ED26-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-3ED26-0AA0 SENTRON MCCB, 2-Pole, 32 A, 75.6

MPN3VA1132-3ED26-0AA0
Active

Siemens SENTRON 3VA1132-3ED26-0AA0, 2-pole molded case circuit breaker, 32 A at 40 °C, 75.6 kA at 240 V AC, TM210 thermal-magnetic release, line protection, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1132-3ED26-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1132-3ED26-0AA0 — Ratings
ParameterValue
Number of poles2
Rated operational voltage Ue (AC)415 V
Rated insulation voltage Ui500 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Power loss, max.7.06 W
3VA1132-3ED26-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1132-3ED26-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1132-3ED26-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1132-3ED26-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1132-3ED26-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width50.8 mm
Depth70 mm
Height (in)5.12 in
Width (in)2 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1132-3ED26-0AA0 is a 2-pole molded case circuit breaker (MCCB) designed for line protection, carrying a 32 A rating at 40 °C and a TM210 thermal-magnetic overcurrent release. Its interrupting capacity reaches 75.6 kA at 240 V AC and 52.5 kA at 415 V AC, giving it the headroom to clear high-fault currents in distribution panels without cascading upstream.

Rated 32 A continuous at ambient temperatures up to 50 °C without derating; at 70 °C it holds 30 A, so a panel running warm still keeps its full 32 A rating through most normal conditions. The 2-pole configuration suits single-phase or two-leg line protection; the TM210 release provides thermal-magnetic trip characteristics for overload and short-circuit coordination. Rated insulation voltage of 500 V AC and operating voltage up to 415 V AC (250 V DC) cover standard low-voltage distribution in North American and IEC markets. Front IP40 protection means it's suited for enclosed panel mounting where tools or fingers won't contact live parts — not for washdown zones.

Rated power loss of 7.06 W maximum is modest for a 32 A MCCB, helping keep enclosure internal temperature rise within limits when multiple breakers are ganged.

Dimensions of 70 mm depth, 50.8 mm width, and 130 mm height fit standard 2-pole MCCB cutouts in distribution panels; the 50.8 mm width matches the common 2-inch per-pole footprint.

Frequently asked questions

What does the TM210 release designation mean?

TM210 indicates a thermal-magnetic overcurrent release with a fixed thermal trip curve and magnetic short-circuit pickup, tailored for line protection in the 3VA platform.

MPN
3VA1132-3ED26-0AA0