Skip to main content
Siemens 3VA1132-3EF32-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-3EF32-0AC0 SENTRON MCCB, 32A, 3-Pole, 75.6kA

MPN3VA1132-3EF32-0AC0

Siemens SENTRON 3VA1, molded case circuit breaker, 3VA1132-3EF32-0AC0, 3-pole, 32 A (40 °C), 75.6 kA at 240 V, TM240 release, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1132-3EF32-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11323EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1132-3EF32-0AC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.10.6 W
3VA1132-3EF32-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1132-3EF32-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1132-3EF32-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1132-3EF32-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1132-3EF32-0AC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

It carries a continuous current rating of 32 A at 40 °C with no derating needed up to 50 °C — at 55 °C it still holds 31 A, and at 70 °C it's good for 30 A, so you're not losing headroom in a warm enclosure. The TM240 overcurrent release handles the thermal-magnetic trip curve for feeder and branch circuit protection. Breaking capacity hits 75.6 kA at 240 V, 52.5 kA at 415 V, and still delivers 11.9 kA at 690 V — that's a lot of fault-interruption muscle for a 32 A frame.

Three-pole construction, 76.2 mm wide, 130 mm tall, 70 mm deep — that's a standard 3-inch wide footprint for a 3-pole MCCB.

Frequently asked questions

What is the breaking capacity of this MCCB at different voltages?

At 240 V it breaks 75.6 kA, at 415 V it breaks 52.5 kA, at 440 V it breaks 32 kA, and at 500 V and 690 V it breaks 11.9 kA. That covers most industrial fault-current scenarios on a 32 A feeder.

Where can I buy 3VA1132-3EF32-0AC0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock figures or lead-time numbers on this page.

What are the physical dimensions of this circuit breaker?

Width is 76.2 mm (3 in), height is 130 mm (5.12 in), depth is 70 mm (2.76 in). Standard 3-pole MCCB footprint for DIN-rail or panel-mount installation.

MPN
3VA1132-3EF32-0AC0