Skip to main content
Siemens 3VA1132-3EF32-0AE0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1132-3EF32-0AE0 Circuit Breaker, 32A, 25kA @ 415V

MPN3VA1132-3EF32-0AE0

Siemens 3VA1 IEC frame 160, breaking capacity class N, 3-pole, 32A, Icu=25kA @ 415V, line protection TM240, ATAM, overload Ir=22A...32A, short-circuit Ii=5...10 x In, with nut keeper kit and 4 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The 3VA1132-3EF32-0AE0 is a Siemens 3VA1 IEC frame 160 molded case circuit breaker with a 32 A thermal-magnetic trip unit (TM240, ATAM). For a 415 V three-phase supply, that puts it in breaking capacity class N, suitable for downstream distribution panels where fault levels are moderate. The overload protection is adjustable from 22 A to 32 A (Ir), and the instantaneous short-circuit pickup (Ii) is set at 5 to 10 times the rated current In — so at the 32 A setting, the magnetic trip fires between 160 A and 320 A.

Deployment context

This breaker mounts in a standard IEC distribution panel or motor control center. The 3-pole construction handles three-phase loads — typical for feeding a sub-distribution board, a group of motor starters, or a large single load like a compressor or chiller. The nut keeper kit and four auxiliary switches (HQ) are factory-fitted, so you get remote status indication (open/closed/tripped) without adding separate accessory modules. The auxiliary switches share the same mounting footprint as the breaker; no extra DIN-rail space is consumed beyond the breaker itself.

Frequently asked questions

Where can I buy 3VA1132-3EF32-0AE0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of this breaker?

The Icu (ultimate short-circuit breaking capacity) is 25 kA at 415 V AC, which is breaking capacity class N per IEC 60947-2. That means it can safely interrupt a fault up to 25,000 A at the rated voltage.

What are the adjustable protection settings on 3VA1132-3EF32-0AE0?

The overload protection (Ir) is adjustable from 22 A to 32 A via the TM240 thermal-magnetic trip unit. The instantaneous short-circuit pickup (Ii) is adjustable from 5 to 10 times the rated current In — so at the 32 A setting, the magnetic trip range is 160 A to 320 A.

MPN